CX-Programmer _Page 116
Displaying Backup status in Status Bar
Displaying the Backup status indicator in the status bar, from the toolbar menu
View|Windows|PLC Memory
Backup Status:
Whenever the connected PLC is backing up data to the Flash ROM, the backup status indicator will be
displayed as follows:
The indicator will flash during the backup operation. When the backup has been completed no indicator is
displayed.
Note:
With the C-series PLCs, any of the following methods can be used for data transfer and
verification with a ROM Writer.
•
Using the CX-Programmer, transfer the program from the computer to the ROM Writer.
•
Transfer to program from the ROM Writer to a CX-Programmer project.
•
Verify programs between CX-Programmer and ROM Writer.
•
Create Intel Hex format files from CX-Programmer programs.
•
Input from an Intel Hex format file to the CX-Programmer project.
Note:
The data transferred for each PLC is listed below.
PLC Data
C1000H/2000H
Program, I/O tables, SYSMAC NET data link tables, battery error
detection method
C200H
Program, I/O tables, Fixed DM, battery error detection method
C200HS
Program, I/O tables, PLC Setup, Expansion DM, expansion instructions
CQM1, CQM1H
Program, PLC Setup, expansion instructions
C200HX/HG/HE (-Z)
Program, I/O tables, PLC Setup, Expansion DM, expansion instructions
Data Trace/Time Chart Monitoring
Once a program has been downloaded into a PLC and is being executed, the program and any associated data
can be graphically traced providing an analytical tool for monitoring program performance.
During the execution of a Data Trace, the PLC records the data values and holds them in an internal buffer.
When the trace is complete, the values are uploaded from the PLC and displayed on the screen.
Select the
Data Trace
button from the toolbar or
Time Chart Monitoring
from the
PLC
menu.
Refer to the
CX-Server PLC Tools User Manual
for further information.
CX-Net Network Configuration Tool
The CX-Net Network Configuration tool provides procedures for establishing communications to PLCs for
direct and gateway connections. It allows the creation and editing of local and network Routing Tables, and the
creation and editing of Data Link Tables.
To open the CX-Net Network Configuration tool, select
Network Configuration Tool
from the
Tools
menu. A
temporary project file (CXP Project.cdm) will be created with the same PLC types in the CX-Programmer
project.
Refer to the
CX-Server PLC Tools User Manual
for further information.
Summary of Contents for CX-Programmer 9
Page 1: ...Cat No W446 E1 10 CX Programmer Ver 9 SYSMAC WS02 CXPC_ V9 OPERATION MANUAL...
Page 2: ......
Page 3: ...SYSMAC WS02 CXPC V9 CX Programmer Ver 9 Operation Manual Revised December 2009...
Page 4: ......
Page 6: ......
Page 19: ...CX Programmer_Page xvi Unit Versions and Lot Numbers...
Page 30: ......
Page 31: ...PART 1 CX Programmer...
Page 32: ......
Page 100: ......
Page 120: ......
Page 198: ...PART 1 CX Programmer CHAPTER 4 Reference OMRON CX Programmer _Page 118...
Page 224: ...PART 1 CX Programmer Keyboard Shortcuts CX Programmer OMRON CX Programmer _Page 144...
Page 240: ......
Page 241: ...PART 2 CX Server PLC Tools...
Page 242: ......
Page 250: ......
Page 256: ......
Page 268: ...PART 2 CX Server PLC Tools CHAPTER 2 PLC Memory Component OMRON CX Server PLC Tools_Page 18...
Page 286: ......
Page 338: ......
Page 382: ......
Page 414: ......
Page 430: ......
Page 436: ......
Page 437: ...PART 3 CX Server Runtime...
Page 438: ......
Page 482: ......
Page 488: ......
Page 504: ......
Page 530: ......
Page 540: ......
Page 541: ......
Page 542: ......