PART 3: CX-Server Runtime
CHAPTER 3 – Communications
OMRON
CX-Server Runtime_Page 34
Revision 2.0
Note 3:
If the CP1W-CIF41 is used, the PLC containing it cannot be used as a gateway PLC to cross
network layers.
Note 4:
Use FINS/UDP for communications with the NS-series PT when using an EtherNet/IP Unit or
built-in EtherNet/IP port on the CPU Unit.
Note 5:
An Option Board can be mounted only to a CPU Unit with 30 or 40 Points.
The CP1E-E
@@
D
@
-A cannot be connected via an NS-series PT because it has no built-in RS-
232C port and an Option Board cannot be mounted.
Setting Procedures
Specifying the PLC to Connect to via the PT
The procedures for connecting the CX-Programmer to a PLC via an NS-series PT are given below. Be sure that
normal communications are possible between the PT and PLC before performing any of these procedures.
Downloading Ladder Programs or Other Data to a PLC with an Ethernet Connection between
the Computer and PT and a 1:N NT Link Serial Connection between the PT and PLC
CX-Programmer NS-series
PT
PLC
Ethernet Serial
1. Start the CX-Programmer.
2. Set the network type in the Change PLC Dialog Box to Ethernet and click the Set Button.
3. Input the IP address of the PT to connect to on the Driver Tab Page of the Network Settings
Dialog Box.
4. Click the
Network
Tab and set the following items.
Item Description
FINS Source Address
Input the local network address of the PT.
FINS Destination Address
Input 111 if the PLC is connected to serial port A on the PT.
Input 112 if the PLC is connected to serial port B on the PT.
Node
Input 1 (fixed). (See note.)
Note:
Data cannot be transferred normally if any value other than 1 is set.
5. After completing the settings, connect online and transfer the ladder programs or other data.
Downloading Ladder Programs or Other Data to a PLC with an Ethernet Connection between
the Computer and PT and a Controller Link Connection between the PT and PLC
CX-Programmer NS-series
PT
PLC
Ethernet
Controller
Link
1. Start the CX-Programmer.
2. Set the network type in the Change PLC Dialog Box to Ethernet and click the Set Button.
3. Input the IP address of the PT to connect to on the Driver Tab Page of the Network Settings
Dialog Box.
Summary of Contents for CX-Programmer 9
Page 1: ...Cat No W446 E1 10 CX Programmer Ver 9 SYSMAC WS02 CXPC_ V9 OPERATION MANUAL...
Page 2: ......
Page 3: ...SYSMAC WS02 CXPC V9 CX Programmer Ver 9 Operation Manual Revised December 2009...
Page 4: ......
Page 6: ......
Page 19: ...CX Programmer_Page xvi Unit Versions and Lot Numbers...
Page 30: ......
Page 31: ...PART 1 CX Programmer...
Page 32: ......
Page 100: ......
Page 120: ......
Page 198: ...PART 1 CX Programmer CHAPTER 4 Reference OMRON CX Programmer _Page 118...
Page 224: ...PART 1 CX Programmer Keyboard Shortcuts CX Programmer OMRON CX Programmer _Page 144...
Page 240: ......
Page 241: ...PART 2 CX Server PLC Tools...
Page 242: ......
Page 250: ......
Page 256: ......
Page 268: ...PART 2 CX Server PLC Tools CHAPTER 2 PLC Memory Component OMRON CX Server PLC Tools_Page 18...
Page 286: ......
Page 338: ......
Page 382: ......
Page 414: ......
Page 430: ......
Page 436: ......
Page 437: ...PART 3 CX Server Runtime...
Page 438: ......
Page 482: ......
Page 488: ......
Page 504: ......
Page 530: ......
Page 540: ......
Page 541: ......
Page 542: ......