4. Each debugging operation can be executed by clicking the corresponding icon in the
toolbar or selecting the corresponding menu command from the menu.
Note:
Set the duration of the step execution during Continuous Step Run operation by selecting
Tools - Options - Continuous Step Interval
in the CX-Programmer.
Automatic Scrolling for Step Run Operation
The Simulator can be set to automatically scroll the display to the paused point in the program when performing
Step Run or Continuous Step Run operation. To set scrolling, select
Tools - Simulation - Always Display
Current Execution Point
.
Break Point List/Jump Function
A break point is a point in the ladder program where execution is paused temporarily. With the CX-One Ver 1.1
(CX-Programmer Ver. 6.1 and CX-Simulator Ver. 1.6), it is possible to list the break points set for the active
project’s PLC and jump to a specified break point position in that list.
1, 2, 3…
1. Select
Tools - Simulation – Break Point List
.
2. The Break Point List Dialog Box will be displayed.
3. Click
the
Jump
,
Delete
, or
Delete All
Button to jump to a point in the list or delete break
points.
PLC-PT Integrated Simulation
When using CX-Programmer Ver. 7.2 or higher (CX-One version 2.1 or higher), the CX-Designer’s offline test
function can be used to debug the interactive operation between a CS/CJ/CP/NSJ-series CPU Unit program and
NS-series PT touch panel screen data.
Note 1:
The PLC – PT integrated simulation can operate only with the combination of a CS/CJ-series,
CP-series, or NSJ-series PLC and an NS-series PT.
2:
This function cannot be used unless the CX-Designer and CX-Simulator are installed when
the CX-One Integrated tool Package is installed.
Select
Simulation
–
PLC-PT Integrated Simulation
. It is also possible to select the CX-Programmer project’s
first PLC in the project workspace, right-click to display the pop-up menu, and select
PLC-PT Integrated
Simulation
.
Note:
The PLC-PT Simulation can also be started from the CX-Designer. Refer to the
CX-Designer
Operation Manual
(Cat. No. V099) for details on starting the simulation program from the
CX-Designer.
PLC Error Simulator
During simulation of ladder programs with CX-Programmer Ver. 7.2 or higher (CX-One version 2.1 or higher),
fatal and non-fatal PLC errors can be generated in a special window to debug ladder program sections that detect
errors.
The error-processing programs can be debugged easily in a separate window.
1. Connect the simulator online in the CX-Programmer, or start the integrated simulation.
2. If the CX-Programmer is used, select
Simulation – PLC Error Simulator
to start the PLC error simulator
program.
3. The PLC Error Simulator Window will be displayed. Select the errors that you want to generate, and press
the General Error Button or Clear Error Button to change the status.
Note:
When the simulator program is stopped, the errors generated up to that point will be cleared.
Working On-line
CX-Programmer permits the connection of the PLC to the computer through the project, and
subsequent additional features once the PLC is on-line. Select the
Work On-line
button from
the toolbar to connect to the PLC.
Summary of Contents for CX-Programmer 9
Page 1: ...Cat No W446 E1 10 CX Programmer Ver 9 SYSMAC WS02 CXPC_ V9 OPERATION MANUAL...
Page 2: ......
Page 3: ...SYSMAC WS02 CXPC V9 CX Programmer Ver 9 Operation Manual Revised December 2009...
Page 4: ......
Page 6: ......
Page 19: ...CX Programmer_Page xvi Unit Versions and Lot Numbers...
Page 30: ......
Page 31: ...PART 1 CX Programmer...
Page 32: ......
Page 100: ......
Page 120: ......
Page 198: ...PART 1 CX Programmer CHAPTER 4 Reference OMRON CX Programmer _Page 118...
Page 224: ...PART 1 CX Programmer Keyboard Shortcuts CX Programmer OMRON CX Programmer _Page 144...
Page 240: ......
Page 241: ...PART 2 CX Server PLC Tools...
Page 242: ......
Page 250: ......
Page 256: ......
Page 268: ...PART 2 CX Server PLC Tools CHAPTER 2 PLC Memory Component OMRON CX Server PLC Tools_Page 18...
Page 286: ......
Page 338: ......
Page 382: ......
Page 414: ......
Page 430: ......
Page 436: ......
Page 437: ...PART 3 CX Server Runtime...
Page 438: ......
Page 482: ......
Page 488: ......
Page 504: ......
Page 530: ......
Page 540: ......
Page 541: ......
Page 542: ......