PART 3: CX-Server Runtime
OMRON
CHAPTER 4 – Import/Export Tool
Revision 2.0
CX-Server Runtime_Page 43
4. Select
the
OK
pushbutton to accept the settings. Select the
Cancel
pushbutton to abort the
operation. Select the
Edit Project
button to edit the CX-Server project's PLC. Point
definitions can also be added to the CX-Server project if desired, before export from this
function.
Refer to Chapter 2 - Introduction to CX-Server Projects
for further information.
Once the OK pushbutton has been selected, the Export Data File dialog is displayed. This
is a standard Microsoft Windows File Open dialog.
5. Insert a filename to export in the
File name
field and click on
OK
or select the
Cancel
pushbutton to abort the operation.
6. A message is displayed in the Import/Export tool that the export is beginning. Another
message is shown indicating the success of the export. The device details of the chosen
PLC are copied to the selected file if the export is successful.
Exporting Data to FinsServer Files
Use the following procedure to export data to FinsServer files.
1, 2, 3…
1. Select
the
Export to TagDB
button from the toolbar. The FinsServer Export Option dialog
is displayed.
2. Select the PLC from the
PLC in Project
field. Details of tags, device type and network
nodes are displayed below the list box.
•
+ The plus icon indicates that tagged data is assigned to the PLC listed in the
Node in
TagDB
field.
•
-
The minus icon indicates that there is no tagged data assigned to the PLC listed in
the
Node in TagDB
field.
3. Set
the
Export to same name PLC
field to use the PLC in the current CX-Server project.
Deselect the
Export to same name PLC
field to select a specific PLC from the
PLC in
Project
field. If necessary, tag details can be edited via the
Edit TagDB
pushbutton.
Details of device type and network nodes are displayed below the drop-down list.
4. Select
the
Export Point
pushbutton. The
Export Point
pushbutton is disabled if the
destination and source PLC types are different. If there are other differences (apart from
PLC type) the export can proceed but no Export Log is generated.
5. Select
the
Close
pushbutton. The success or failure of the import operation is displayed
in the Import/Export tool status dialog. Select the
OK
pushbutton to proceed.
Summary of Contents for CX-Programmer 9
Page 1: ...Cat No W446 E1 10 CX Programmer Ver 9 SYSMAC WS02 CXPC_ V9 OPERATION MANUAL...
Page 2: ......
Page 3: ...SYSMAC WS02 CXPC V9 CX Programmer Ver 9 Operation Manual Revised December 2009...
Page 4: ......
Page 6: ......
Page 19: ...CX Programmer_Page xvi Unit Versions and Lot Numbers...
Page 30: ......
Page 31: ...PART 1 CX Programmer...
Page 32: ......
Page 100: ......
Page 120: ......
Page 198: ...PART 1 CX Programmer CHAPTER 4 Reference OMRON CX Programmer _Page 118...
Page 224: ...PART 1 CX Programmer Keyboard Shortcuts CX Programmer OMRON CX Programmer _Page 144...
Page 240: ......
Page 241: ...PART 2 CX Server PLC Tools...
Page 242: ......
Page 250: ......
Page 256: ......
Page 268: ...PART 2 CX Server PLC Tools CHAPTER 2 PLC Memory Component OMRON CX Server PLC Tools_Page 18...
Page 286: ......
Page 338: ......
Page 382: ......
Page 414: ......
Page 430: ......
Page 436: ......
Page 437: ...PART 3 CX Server Runtime...
Page 438: ......
Page 482: ......
Page 488: ......
Page 504: ......
Page 530: ......
Page 540: ......
Page 541: ......
Page 542: ......