PART 1: CX-Programmer
OMRON
CHAPTER 6 – Converting a C500/C120/C**P Program to CS/CJ/CP/CVM1 Format
CX-Programmer _Page 129
Before conversion
After conversion
C500
/C120
C**P
Example
CS/CJ
Series
Example
CV Series
Example
Remarks
FUN75
FUN75 00 10
SRD
SRD 0000 0010
SRD
SRD 0000 0010
FUN75
is converted to its
corresponding instruction,
SRD
.
FUN76
FUN76 00 #0021 10
MLPX
MLPX 0000 #0021 0010
MLPX
MLPX 0000 #0021 0010
FUN76
is converted to its
corresponding instruction,
MLPX
.
FUN77
FUN77 00 10 #0012
DMPX
DMPX 0000 0010 #0012
DMPX
DMPX 0000 0010 #0012
FUN77
is converted to its
corresponding instruction,
DMPX
.
FUN78
FUN78 00 #0013 10
SDEC
SDEC 0000 #0013 0010
SDEC
SDEC 0000 #0013 0010
FUN78
is converted to its
corresponding instruction,
SDEC
.
FUN79
FUN79 00 05 10
FDIV
FDIV 0000 0005 0010
FDIV
FDIV 0000 0005 0010
FUN79
is converted to its
corresponding instruction,
FDIV
.
FUN80
FUN80 #0010 05 #1010
DISTC
DISTC #10 5 #1010
DIST
DIST #0010 0005 #1010
- For CS/CJ-H PLCs,
FUN80
is converted to its
corresponding instruction,
DISTC
.
- For the CV Series,
FUN80
is converted to its
corresponding instruction,
DIST
.
FUN81
FUN81 10 #10 20
COLLC
COLLC 10 #0010 20
COLL
COLL 0010 #0010 0020
- For CS/CJ-H PLCs,
FUN81
is converted to its
corresponding instruction,
COLLC
.
- For the CV Series,
FUN81
is converted to its
corresponding instruction,
COLL
.
FUN82
FUN82 #6537 #1515 00
MOVBC
MOVBC #6537 #1515 0
MOVB
MOVB #6537 #1515
0000
- For CS/CJ-H PLCs,
FUN82
is converted to its
corresponding instruction,
MOVBC
.
- For the CV Series,
FUN82
is converted to its
corresponding instruction,
MOVB
.
FUN83
FUN83 #0100 #0201 10
MOVD
MOVD #100 #201 10
MOVD
MOVD #0100 #0201
0010
FUN83
is converted to its
corresponding instruction,
MOVD
.
FUN84
FUN84 35 10 20
SFTR
SFTR 35 10 20
SFTR
SFTR 0035 0010 0020
FUN84
is converted to its
corresponding instruction,
SFTR
.
FUN85
FUN85 #1000 40 50
TCMP
TCMP #1000 40 50
TCMP
TCMP #1000 0040 0050
FUN85
is converted to its
corresponding instruction,
TCMP
.
FUN87
FUN87 #0050 10 05
IOWR
IOWR 10 &0050 0005
WRIT
WRIT #0050 0010 0005
- The following message will
appear for CS/CJ-H PLCs:
“CONVERT_WARNING:
The instruction specification
is different. Check the
instructions.” Check the
specifications of CPU Unit
after conversion.
- For CJ/CS-H PLCs,
FUN87
is converted to its
corresponding instruction,
IOWR
.
- For CJ/CS-H PLCs, the
first and second operands
are interchanged.
- For CS/CJ-H PLCs, the
second operand is
converted from BCD data
(#0050) to unsigned
decimal data (&0050).
- For the CV Series,
FUN87
is converted to its
corresponding instruction,
WRIT
.
Summary of Contents for CX-Programmer 9
Page 1: ...Cat No W446 E1 10 CX Programmer Ver 9 SYSMAC WS02 CXPC_ V9 OPERATION MANUAL...
Page 2: ......
Page 3: ...SYSMAC WS02 CXPC V9 CX Programmer Ver 9 Operation Manual Revised December 2009...
Page 4: ......
Page 6: ......
Page 19: ...CX Programmer_Page xvi Unit Versions and Lot Numbers...
Page 30: ......
Page 31: ...PART 1 CX Programmer...
Page 32: ......
Page 100: ......
Page 120: ......
Page 198: ...PART 1 CX Programmer CHAPTER 4 Reference OMRON CX Programmer _Page 118...
Page 224: ...PART 1 CX Programmer Keyboard Shortcuts CX Programmer OMRON CX Programmer _Page 144...
Page 240: ......
Page 241: ...PART 2 CX Server PLC Tools...
Page 242: ......
Page 250: ......
Page 256: ......
Page 268: ...PART 2 CX Server PLC Tools CHAPTER 2 PLC Memory Component OMRON CX Server PLC Tools_Page 18...
Page 286: ......
Page 338: ......
Page 382: ......
Page 414: ......
Page 430: ......
Page 436: ......
Page 437: ...PART 3 CX Server Runtime...
Page 438: ......
Page 482: ......
Page 488: ......
Page 504: ......
Page 530: ......
Page 540: ......
Page 541: ......
Page 542: ......