Misure di
sicurezza
(unità: mm/inch)
Dimensioni dell’unità esterna
W × H × D
Dimensioni di montaggio
Distanza A Distanza B
760x590x285 (29,9x23,2x11,2)
530 (20,85)
290 (11,4)
810x558x310 (31,9x22x12.2)
549 (21,6)
325 (12,8)
845x700x320 (33,27x27,5x12,6)
560 (22)
335 (13,2)
900x860x315 (35,4x33,85x12,4)
590 (23,2)
333 (13,1)
945x810x395 (37,2x31,9x15,55)
640 (25,2)
405 (15,95)
990x965x345 (38,98x38x13,58)
624 (24,58)
366 (14,4)
938x1369x392 (36,93x53,9x15,43)
634 (24,96)
404 (15,9)
900x1170x350 (35,4x46x13,8)
590 (23,2)
378 (14,88)
800x554x333 (31,5x21,8x13,1)
514 (20,24)
340 (13,39)
845x702x363 (33,27x27,6x14,3)
540 (21,26)
350 (13,8)
946x810x420 (37,2x31,9x16,53)
673 (26,5)
403 (15,87)
946x810x410 (37,2x31,9x16,14)
673 (26,5)
403 (15,87)
952x1333x410 (37,5x52,5x16,14)
634 (24,96)
404 (15,9)
952x1333x415 (37,5x52,5x16,14)
634 (24,96)
404 (15,9)
890 x 673 x 342 (35,0"x26,5"x13,5")
663 (26,1)
354 (13,9)
Righe di installazione della serie
Le relazioni tra H, A e L sono le seguenti.
L
A
L ≤ H
L ≤ 1/2H
25 cm / 9,8” o più
1/2H < L ≤ H
30 cm / 11,8” o più
L > H
Non può essere installato
L
H
A
300 cm / 1
18” o più
60 cm / 23,6”
o più
150 cm / 59”
o più
25 cm / 9,8”
o più
25 cm / 9,8”
o più
Indicazione sulla perforazione nella parete
È necessario praticare un foro nella parete per le
tubazioni del refrigerante e il cavo di segnale, che
collegheranno le unità interne ed esterne.
1. Determinare la posizione del foro del muro in
base alla posizione dell'unità esterna.
2. Usare un trappano da 65 mm (2,5") per
praticare un foro nella parete.
NOTA:
Quando fora la parete, assicurarsi di
evitare fili, impianti idraulici e altri componenti
sensibili.
3. Posizionare il paramano nel foro. Questo
protegge i bordi del foro e aiuterà a sigillare
quando si finisce il processo di installazione.
Quando si seleziona un'unità interna 24K
L'unità interna 24K può essere collegata solo con
un sistema A. Se ci sono due unità interne 24K,
possono essere collegate con sistemi A e B.
Dimensione del tubo connettivo di un sistema
A e B
(unità di misura: pollici)
Capacità dell’unità interna (Btu/
h)
Liquido
Gas
7K/9K/12K
1/4
3/8
12K/18K
1/4
1/2
24K
3/8
5/8
Pagina 23
Installazione unità
esterna
TOGLIERE
togliere 7k
b
a
ENGLISH
EN - 18
7.5 - NOTES ON DRILLING HOLE IN WALL
It is necessary to drill a hole into the wall for the passage of the refrigerant piping
and of the signal cable between the internal and external units.
1.
Determine the position of the hole in the wall based on the position of the external
unit.
2.
Drill a hole in the wall of at least 65mm.
When drilling the wall hole, make sure to avoid wires, plumbing, and
other sensitive components.
3.
Protect the hole edges to preserve the tubes and the cables.
Indoor Unit capacity
(Btu/h)
Liquid
(in)
Gas
(in)
9K/12K
1/4
3/8
12K
1/4
1/2
7.6 - REFRIGERANT PIPING CONNECTION
When connecting refrigerant piping, do not let substances or gases other than the specified refrigerant enter
the unit.
The presence of other gases or substances will lower the unit’s capacity, and can cause abnormally high
pressure in the refrigeration cycle.
This can cause explosion and injury.
• The branching pipe must be installed horizontally. An angle of more than 10° may cause
malfunction.
• DO NOT install the connecting pipe until both indoor and outdoor units have been installed.
• Insulate both the gas and liquid piping to prevent water leakage.
7.6.1 - Step 1: Cut pipes
When preparing refrigerant pipes, take extra care to cut and flare them properly. This will ensure efficient
operation and minimize the need for future maintenance.
1.
Measure the distance between the indoor and outdoor units.
2.
Cut the piping sections abounding by approximately 3÷4 cm on the length.
Use a wheel pipe cutter only to cut the pipes clamping it in short lengths so as not
to crush the pipe.
NEVER USE A NORMAL HANDSAW, scraps could fall inside the pipe and enter the circuitry
of the system, damaging the parts severely.
Summary of Contents for ARYAL S2 E
Page 2: ......
Page 190: ...EL 2 0 1 1 OL PIA SPLENDID 2 3 4 5 6 7 8 9 10...
Page 198: ...EL 10 4 3 COOL HEAT TIMERON 5 5 1 5 2 3...
Page 199: ...ARYAL S2 E DUAL TRIAL EL 11 7 C 5 3 1 a 3 b 4 10 2 COOL...
Page 200: ...EL 12 3 4 5 6 FAN 7 80 8 9 3 10 6 Q ty pc 2 4 1 Q ty pc 5 8 A 5 8...
Page 209: ...ARYAL S2 E DUAL TRIAL EL 21 7 8 9 8 90 110 1 32 ohms 0 OFF...
Page 213: ...ARYAL S2 E DUAL TRIAL EL 25 9 1 1 2M 2 4 3 1 2 A B C A B DUAL A B C TRIAL 9 2 a i 1 2 3 4 a...
Page 215: ......
Page 216: ...264710B...