![Nortel CallPilot 1001rp Installation And Configuration Manual Download Page 252](http://html1.mh-extra.com/html/nortel/callpilot-1001rp/callpilot-1001rp_installation-and-configuration-manual_1707126252.webp)
Performing RAID maintenance
Standard 1.0
252
CallPilot
8
Click OK in the Rebuild Drive dialog box, and then click OK in the Rebuild
Progress dialog box to return to the Device Selection dialog box.
Result:
The rebuilt drive is shown as being online (ONL).
9
Repeat steps 7 and 8 for the remaining two dead drives.
10
Once all hard drives have been rebuilt, click OK in the Device Selection
dialog box to return to the DAC Administration Utility window. Then exit
the DAC Administration Utility.
Result:
You have completed the upgrade procedure.
Reverting to the pre-upgrade system (if the upgrade fails)
This section describes how to restore the CallPilot server to the state it was
in before you began the upgrade. This procedure includes the following
steps:
1. Mark the failed upgrade hard drives dead.
2. Reconnect the pre-upgrade hard drives.
3. Enable the pre-upgrade hard drives and restore the pre-upgrade software.
To mark the failed upgrade hard drives dead
1
Insert the CallPilot 2.0 OS Recovery or OS Upgrade CD into the CD-
ROM drive and then power up the computer.
Note:
In order for this procedure to work the computer BIOS must have
booting from CD-ROM enabled. You may need to enter the BIOS setup
to enable booting from CD-ROM.
Result:
The system boots and the "MS-DOS 6.2 Start Menu" is
displayed.
2
Use the up and down arrow keys to select "8. Other Utilities (BIOS,
firmware, Etc.)..." and press Enter.
Result:
The "*** Other Utilities ***" menu is displayed.
3
Press 3 to select "3. Mylex DAC960 RAID Card Configuration Utility".
Result:
The DAC960 Configuration Utility main menu appears.
Summary of Contents for CallPilot 1001rp
Page 2: ...P0949455...
Page 6: ...vi CallPilot Publication history Standard 1 0...
Page 38: ...Troubleshooting your CallPilot system Standard 1 0 38 CallPilot...
Page 62: ...Using Windows NT online diagnostic tools Standard 1 0 62 CallPilot...
Page 74: ...Using serial port diagnostic tools Standard 1 0 74 CallPilot...
Page 88: ...Using CallPilot Manager to monitor hardware Standard 1 0 88 CallPilot...
Page 114: ...Using CallPilot Manager to monitor hardware Standard 1 0 114 CallPilot...
Page 150: ...Replacing basic chassis components Standard 1 0 150 CallPilot...
Page 168: ...Replacing a hard drive tape drive CD ROM drive or floppy drive Standard 1 0 168 CallPilot...
Page 178: ...Performing RAID maintenance Standard 1 0 178 CallPilot...
Page 260: ...Performing RAID maintenance Standard 1 0 260 CallPilot...
Page 274: ...Replacing or adding voice processing boards Standard 1 0 274 CallPilot...
Page 280: ...Replacing the video card Standard 1 0 280 CallPilot...
Page 292: ...Replacing the network cards Standard 1 0 292 CallPilot...
Page 320: ...Maintaining the Pentium II SBC card Standard 1 0 320 CallPilot Pentium II SBC...
Page 348: ...Maintaining the Pentium III SBC card Standard 1 0 348 CallPilot...
Page 367: ......