![Nortel CallPilot 1001rp Installation And Configuration Manual Download Page 248](http://html1.mh-extra.com/html/nortel/callpilot-1001rp/callpilot-1001rp_installation-and-configuration-manual_1707126248.webp)
Performing RAID maintenance
Standard 1.0
248
CallPilot
To disconnect the dead hard drives
Physically disconnect the hard drives marked DED to ensure that these hard
drives are not updated during the upgrade and are preserved as a backup.
1
Shut down and power off the CallPilot server.
2
Disconnect the hard drives marked DED by unseating them from the
hard drive bays 4, 5, and 6 (counting bays from left to right), but do not
remove them. See the following example:
3
Power up the server.
Note:
During the bootup, the system reports that three hard drives are
dead, and, as a result, three system drives are running in critical state.
This is normal. It indicates that the disks are no longer being mirrored. If
you run the DACMon Utility, it also reports that three hard drives are
dead and that they are not being replaced by a hot standby.
Performing the CallPilot server software upgrade
You can now perform the upgrade operation, and only one disk of each pair
will be updated. This allows you to maintain a copy of the system in its
previous state in case there are problems during the upgrade process.
Summary of Contents for CallPilot 1001rp
Page 2: ...P0949455...
Page 6: ...vi CallPilot Publication history Standard 1 0...
Page 38: ...Troubleshooting your CallPilot system Standard 1 0 38 CallPilot...
Page 62: ...Using Windows NT online diagnostic tools Standard 1 0 62 CallPilot...
Page 74: ...Using serial port diagnostic tools Standard 1 0 74 CallPilot...
Page 88: ...Using CallPilot Manager to monitor hardware Standard 1 0 88 CallPilot...
Page 114: ...Using CallPilot Manager to monitor hardware Standard 1 0 114 CallPilot...
Page 150: ...Replacing basic chassis components Standard 1 0 150 CallPilot...
Page 168: ...Replacing a hard drive tape drive CD ROM drive or floppy drive Standard 1 0 168 CallPilot...
Page 178: ...Performing RAID maintenance Standard 1 0 178 CallPilot...
Page 260: ...Performing RAID maintenance Standard 1 0 260 CallPilot...
Page 274: ...Replacing or adding voice processing boards Standard 1 0 274 CallPilot...
Page 280: ...Replacing the video card Standard 1 0 280 CallPilot...
Page 292: ...Replacing the network cards Standard 1 0 292 CallPilot...
Page 320: ...Maintaining the Pentium II SBC card Standard 1 0 320 CallPilot Pentium II SBC...
Page 348: ...Maintaining the Pentium III SBC card Standard 1 0 348 CallPilot...
Page 367: ......