![Nortel CallPilot 1001rp Installation And Configuration Manual Download Page 207](http://html1.mh-extra.com/html/nortel/callpilot-1001rp/callpilot-1001rp_installation-and-configuration-manual_1707126207.webp)
October 2002
Performing RAID maintenance
Part 5: 1001rp Server Maintenance and Diagnostics
207
To perform the CallPilot server software upgrade
1
Upgrade the CallPilot server software. Follow the instructions in Part 4 of
the
CallPilot Installation and Configuration
binder.
2
After the upgrade is completed, ensure that you test the upgrade before
you resynchronize the hard drives. See “Testing the CallPilot installation”
in Part 3 of the
CallPilot Installation and Configuration
binder.
3
Once the upgrade is completed and tested, there are two options
available:
If the upgrade is successful, continue with “Resynchronizing the
CallPilot server hard drives” on page 207 to keep the upgraded
software.
If the upgrade fails, follow the steps in “Reverting to the pre-upgrade
system (if the upgrade fails)” on page 211.
Resynchronizing the CallPilot server hard drives
After you upgrade the server software and test the upgrade, follow the steps
below to resynchronize the hard drives.
To resynchronize the CallPilot server hard drives
1
Shut down and power off the CallPilot server.
2
Reconnect the hard drives by reseating them into their drive bays.
3
Power up the server.
Result:
POST messages from the RAID controller warn you that the
system is operating in critical mode (that is, with some drives offline).
.
CAUTION
Risk of data loss
You can run CallPilot for any period of time before making this
decision. However, during this time, there is no disk
redundancy. Therefore, if a hard drive fails during this time, any
new data is lost.
Summary of Contents for CallPilot 1001rp
Page 2: ...P0949455...
Page 6: ...vi CallPilot Publication history Standard 1 0...
Page 38: ...Troubleshooting your CallPilot system Standard 1 0 38 CallPilot...
Page 62: ...Using Windows NT online diagnostic tools Standard 1 0 62 CallPilot...
Page 74: ...Using serial port diagnostic tools Standard 1 0 74 CallPilot...
Page 88: ...Using CallPilot Manager to monitor hardware Standard 1 0 88 CallPilot...
Page 114: ...Using CallPilot Manager to monitor hardware Standard 1 0 114 CallPilot...
Page 150: ...Replacing basic chassis components Standard 1 0 150 CallPilot...
Page 168: ...Replacing a hard drive tape drive CD ROM drive or floppy drive Standard 1 0 168 CallPilot...
Page 178: ...Performing RAID maintenance Standard 1 0 178 CallPilot...
Page 260: ...Performing RAID maintenance Standard 1 0 260 CallPilot...
Page 274: ...Replacing or adding voice processing boards Standard 1 0 274 CallPilot...
Page 280: ...Replacing the video card Standard 1 0 280 CallPilot...
Page 292: ...Replacing the network cards Standard 1 0 292 CallPilot...
Page 320: ...Maintaining the Pentium II SBC card Standard 1 0 320 CallPilot Pentium II SBC...
Page 348: ...Maintaining the Pentium III SBC card Standard 1 0 348 CallPilot...
Page 367: ......