NORDAC BASE (SK 180E / SK 190E) – Users Manual for Frequency Inverters
166
BU 0180 en-4118
20.7
Illegal Inst.
Access
"Illegal instruction access"
20.8
Program memory error
"
Program memory error
"
(EEPROM error)
20.9
Dual-ported RAM
21.0
NMI error
(Not used by hardware)
21.1
PLL error
21.2
ADU error
"Overrun"
21.3
PMI error
"Access Error"
21.4
Userstack overflow
E022
---
Reserved
Error message for PLC
see supplementary instructions
E023
---
Reserved
Error message for PLC
see supplementary instructions
E024
---
Reserved
Error message for PLC
see supplementary instructions
Warning messages
Display in the
SimpleBox / ControlBox Warning
Text in the ParameterBox
Cause
•
Remedy
Group
Details in P700
[-02]
C001
1.0
Overtemp.
Inverter
"Inverter overtemperature"
(inverter heat sink)
Inverter temperature monitoring
Warning: permissible temperature limit reached.
•
Reduce ambient temperature
•
Check the FI fan / control cabinet ventilation
•
Check the FI for dirt
C002
2.0
Overtemp. Motor PTC
"Overtemperature motor
thermistor "
Warning from motor temperature sensor (triggering
threshold reached)
• Reduce motor load
• Increase motor speed
• Use external motor fan
2.1
Overtemp. Motor I²t
"Motor overtemperature I²t"
Only if I
2
t motor (P535) is
programmed.
Warning: I2t- motor monitoring (1.3 times the rated current
reached for the time period specified in (P535))
• Reduce motor load
• Increase motor speed
2.2
Overtemp. Brake r.ext
"Overtemperature of external
brake resistor "
Overtemperature via digital
input (P420 […])={13}
Warning: Temperature monitor (e.g. brake resistor) has
activated
• Digital input is Low
Summary of Contents for SK 180E Series
Page 1: ...BU 0180 en NORDAC BASE SK 180E SK 190E Users Manual for Frequency Inverters...
Page 4: ...NORDAC BASE SK 180E SK 190E Users Manual for Frequency Inverters 4 BU 0180 en 4118...
Page 185: ...8 Additional information BU 0180 en 4118 185 8 3 4 EU Declaration of Conformity...
Page 211: ...Key word index BU 0180 en 4118 211...
Page 212: ...6071802 4118...