3 Display, operation and options
BU 0180 en-4118
69
Connector (selection)
Type
Data
Designation
Material no.
Document
Power input
500 V, 16 A
SK TIE4-HANQ8-K-LE-MX
275 135 030
Power input
500 V, 16 A
SK TIE4-HAN10E-M1B-LE
275 135 070
Power input
500 V, 16 A
SK TIE4-HAN10E-M2B-LE
275 135 000
Power input
690 V, 20 A
SK TIE4-QPD_3PE-K-LE
275 274 125
Power input
630 V, 16 A
SK TIE4-NQ16-K-LE
275 274 133
Power input +
power outlet
400 V, 16 A
SK TIE4-2HANQ5-K-LE-LA
275 274 110
Power input +
motor outlet
600 V, 16 A
SK TIE4-2HANQ5-M-LE-MA-001
275 274 123
Power output
500 V, 16 A
SK TIE4-HAN10E-M2B-LA
275 135 010
Power output
500 V, 16 A
SK TIE4-HANQ8-K-LA-MX
275 135 040
Motor output
500 V, 16 A
SK TIE4-HAN10E-M2B-MA
275 135 020
Motor output
500 V, 16 A
SK TIE4-HANQ8-K-MA-MX
275 135 050
Information
Looping of the mains voltage
The permissible current load for the connection terminals, plugs and supply cables must be observed when
looping the mains voltage. Failure to comply with this will result in thermal damage to current-carrying modules
and the immediate vicinity thereof.
3.2.3.2 Plug connectors for control connection
Various M12 round plug connectors are available as
flanged plugs or flanged sockets. The plug connectors
are intended for installation in an M16 cable gland of the
device, or in an external technology unit. The protection
class (IP67) of the plug connector only applies in the
screwed state. Similarly to the use of coding pins /
grooves, the colour coding of the connectors (plastic
unit inside and cover caps) is based on functional
requirements and is intended to avoid erroneous
operation.
Suitable expansion and reducer adapters are available
for installation in M12 and M20 cable glands.
Information
Control unit overload
The control unit of the device can be overloaded and destroyed if the 24 V DC supply terminals of the device are
connected to another voltage source
For this reason, particularly when installing connectors for the control connection it must be ensured that any
cores for the 24 V DC power supply are not connected to the device but are insulated accordingly (example of
connector for system bus connection SK TIE4-M12-SYSS).
Summary of Contents for SK 180E Series
Page 1: ...BU 0180 en NORDAC BASE SK 180E SK 190E Users Manual for Frequency Inverters...
Page 4: ...NORDAC BASE SK 180E SK 190E Users Manual for Frequency Inverters 4 BU 0180 en 4118...
Page 185: ...8 Additional information BU 0180 en 4118 185 8 3 4 EU Declaration of Conformity...
Page 211: ...Key word index BU 0180 en 4118 211...
Page 212: ...6071802 4118...