7 Technical data
BU 0180 en-4118
175
Device type
SK 1x0E…
-750-323-
-111-323-
-151-323-
Size
2
2
2
Nominal motor power
(4-pole standard motor)
230 V
0.75 kW
1.10 kW
1.5 kW
240 V
1 hp
1½ hp
2 hp
Mains voltage
230 V
1/3 AC
3 AC
200 … 240 V,
±
10%, 47 … 63 Hz
Input current
rms
10.6 / 7.0 A
14.0 / 9.2 A
11.2 A
FLA
10.6 / 7.0 A
14.0 / 9.2 A
11.2 A
Output voltage
230 V
3 AC
0 … Mains voltage
Output current
1)
rms
4.0 A
5.5 A
7.0 A
FLA
motor mounting
3.9 A
(S1-40°C)
5.4 A
(S1-40°C)
6.9 A
(S1-40°C)
FLA
wall mounting
3.9 A
(S1-40°C)
5.4 A
a)
(S1-30°C)
6.9 A
(S1-40°C)
Min. braking resistor
Accessories
100
Ω
100
Ω
75
Ω
Motor-mounted (ventilated)
Max. continuous power / max. continuous current:
(deviating value for 1~ operation in brackets)
S1-50°C
S1-40°C
0.75kW / 4.0A (3.4A)
0.75kW / 4.0A
0.75kW / 4.2A
1.1kW / 5.4A
1.1kW / 5.5A
1.5kW / 7.0A
Max. permissible ambient temp. with nominal output current
S1
S3 70% ED 10 min
S6 70% ED 10 min (100% / 20% Mn)
1~ 40°C / 3~ 50°C
50°C
50°C
40°C
50°C
50°C
40°C
50°C
50°C
Wall mounting (unventilated)
Max. continuous power / max. continuous current:
(deviating value for 1~ operation in brackets)
S1-50°C
S1-40°C
0.75kW / 4.0A (3.4A)
0.75kW / 4.0A
0.75kW / 4.0A (3.6A)
0.75kW / 4.5A (4.4A)
1.1kW / 5.5A
1.5kW / 6.5A
Max. permissible ambient temp. with nominal output current
S1
S3 70% ED 10 min
S6 70% ED 10 min (100% / 20% Mn)
1~ 40°C / 3~ 45°C
50°C
50°C
1~ 30°C / 3~ 40°C
1~ 40°C / 3~ 50°C
1~ 40°C / 3~ 50°C
30°C
40°C
40°C
General fuses (AC) (recommended)
slow-blowing
16 A
16 A
16 A
Isc
2)
[A]
UL fuses (AC) – permitted
Class
10 00
0
65 00
0
100 0
00
Fus
e
3)
RK5
(x)
x
30 A
30 A
30 A
CC, J, R, T, G, L
(x)
x
30 A
30 A
30 A
CB
4)
(≥
230 V)
x
30 A
30 A
30 A
1) FLA motor installation: relates to a motor with fan
2) Maximum permissible mains overload current
3) The use of a SK TU4-MSW(-…) module limits the permissible short circuit current in the mains to 10 kA
4) "inverse time trip type" in accordance with UL 489
a) FLA: 4.4 A (S1-40°C)
Summary of Contents for SK 180E Series
Page 1: ...BU 0180 en NORDAC BASE SK 180E SK 190E Users Manual for Frequency Inverters...
Page 4: ...NORDAC BASE SK 180E SK 190E Users Manual for Frequency Inverters 4 BU 0180 en 4118...
Page 185: ...8 Additional information BU 0180 en 4118 185 8 3 4 EU Declaration of Conformity...
Page 211: ...Key word index BU 0180 en 4118 211...
Page 212: ...6071802 4118...