5 Parameter
BU 0180 en-4118
135
P506
Automatic error
acknowledgement
(Automatic error acknowledgement)
S
0 ... 7
{ 0 }
In addition to the manual error acknowledgement, an automatic one can also be selected.
0 =
No automatic
error acknowledgement.
1 ... 5 = Number
of permissible automatic error acknowledgements within one mains-on cycle.
After mains off and switch on again, the full amount is again available.
6 =
Always:
an error message will always be acknowledged automatically if the cause of
the error is no longer present.
7 =
Via Deactivate enable:
acknowledgement is only possible using the OK / ENTER key
or by mains switch-off. No acknowledgement is implemented by removing the enable!
NOTE:
If (P428) is parameterised to "ON", parameter (P506) "Automatic error acknowledgement"
must not be parameterised to setting 6 "Always" as otherwise the device or system is endangered
due to the possibility of continuous restarting in the case of an active error (e.g. short-circuit to
earth / short circuit).
P509
Control word source
(Control word source)
S
0 ... 4
{ 0 }
Selection of the interface via which the FI is controlled.
0 =
Control terminals
or keyb. cont.
,
"Control terminals or keyboard control"
**
with the
SimpleBox (if P510=0), the ParameterBox or via BUS I/O bits.
1 =
Only control terminals *
, the FI can only be controlled via the digital and analogue inputs
or via the bus I/O Bits.
2 =
USS *
, the control signals (enable, rotation direction, etc.) are transferred via the RS485
interface, and the setpoint is transferred via the analogue input or the fixed frequencies.
3 =
System bus *
, setting for actuation by master via a bus interface
4 =
System bus broadcast *
, setting for actuation by a master drive in Master / Slave mode
(e.g. with synchronous applications)
*) Keyboard control (SimpleBox, ParameterBox) is disabled, parameterisation is still
possible.
**) If communication is interrupted during keyboard control (timeout 0.5 sec), the FI will
block without an error message.
NOTE:
For details of the optional bus systems, please refer to the relevant supplementary bus manuals.
P510
[-01]
[-02]
Setpoints source
(Setpoints source)
S
0 ... 4
{ [-01] = 0 }
{ [-02] = 0 }
Selection of the setpoint source to be parameterised.
[-01] = Main setpoint source
[-02] =
Subsidiary setpoint source
Selection of the interface via which the FI receives the setpoint.
0 = Auto:
The source of the setpoint is
automatically derived from the setting of
parameter P509.
2 = USS
, see P509
3 = System bus
, see P509
1 = Only control terminals
, digital and
analogue inputs control the frequency,
including fixed frequencies
4 = System bus broadcast
, see P509
Summary of Contents for SK 180E Series
Page 1: ...BU 0180 en NORDAC BASE SK 180E SK 190E Users Manual for Frequency Inverters...
Page 4: ...NORDAC BASE SK 180E SK 190E Users Manual for Frequency Inverters 4 BU 0180 en 4118...
Page 185: ...8 Additional information BU 0180 en 4118 185 8 3 4 EU Declaration of Conformity...
Page 211: ...Key word index BU 0180 en 4118 211...
Page 212: ...6071802 4118...