Page | 35
Figure 28
3.
The default
Reference Type
in the Genlock settings is
SD (Bi-level)
, as this is by far the
most common reference signal type. However, if you supply an HD reference signal to
the Genlock input, change the setting to
HD (Tri-level)
.
4.
With the aid of downstream
Waveform
and
Vector Scopes
, adjust TriCaster’s
Horizontal
and
Vertical Position
and
Phase
settings in the
Genlock
section of the
I/O Configuration
panel.
Again, ideally both the cameras and the TriCaster should be genlocked. If they are not genlocked
to the same reference signal as the TriCaster output, a TBC (Time Base Correction) operation is
applied. Time Base Correction may drop or insert frames as necessary to maintain sync, hence it
is a less desirable approach.
Note: For a deeper explanation of genlocking, please see Section 8.1.5.