V
PP
Operation Mode
0 V
Normal operation mode
7.8 V
Flash memory programming mode
V
PP
RESET
Flash memory programming mode
7.8 V
3 V
0 V
1
2
…
…
…
…
n
16.6.3 Selection of communication mode
In the V850/SA1, a communication system is selected by inputting pulse (16 pulses max.) to V
PP
pin after
switching to the flash memory programming mode. The V
PP
pulse is generated by the dedicated flash writer.
The following shows the relation between the number of pulses and the communication systems.
Table 16-1. List of Communication Systems
V
PP
Pulse
Communication System
Remarks
0
CSI0
V850/SA1 performs slave operation, MSB first
8
UART0
Communication rate: 9600 bps (at reset), LSB first
Others
RFU
Setting prohibited
Caution
When UART is selected, the receive clock is calculated based on the reset command sent from
the dedicated flash writer after receiving V
PP
pulse.
16.6.4 Communication command
The V850/SA1 communicates with the dedicated flash writer by means of commands. The command sent from
the dedicated flash writer to the V850/SA1 is called a “command”. The response signal sent from the V850/SA1 to
the dedicated flash writer is called a “response command”.
V850/SA1
Command
Dedicated flash writer
Response command