CHAPTER 7 TIMER/COUNTER FUNCTION
183
Figure 7-37. Format of 8-Bit Timer Mode Control Register 2-5 (TMC2-TMC5) (1/2)
After reset: 04H
R/W
Address: TMC2 FFFFF246H
TMC3 FFFFF256H
TMC4 FFFFF266H
TMC5 FFFFF276H
7
6
5
4
3
2
1
0
TMCn
TCEn
TMCn6
0
TMCn4
LVSn
LVRn
TMCn1
TOEn
(n = 2-5)
TCEn
TMn Count Control
0
Counting is disabled after the counter is cleared to 0 (prescaler disabled).
1
Start counting
TMCn6
TMn Operating Mode Selection
0
Clear and start mode when TMn and CRn0 match
1
PWM (free running) mode
TMCn4
Individual Mode or Cascade Connection Mode Selection
0
Individual mode (used by the lowest-order timer) (fixed to 0 when n = 2, 4)
1
Cascade connection mode (connection with low-order timer)
LVSn
LVRn
Setting the State of the Timer Output Flip-Flop
0
0
No change
0
1
Reset the timer output flip-flop (to 0).
1
0
Set the timer output flip-flop (to 1).
1
1
Setting prohibited
TMCn1
Not PWM Mode (TMCn6 = 0)
PWM Mode (TMCn6 = 1)
Timer flip-flop control
Active level selection
0
Disable inversion operation
Active high
1
Enable inversion operation
Active low