4-16 Configuring Your Server
Option
Parameter
Description
Your Setting
Post Error Pause
Disabled
[Enabled]
Specify whether to stop the POST once
at the end of POST if an error occurs
during the POST.
AC-LINK
Stay Off
[Last State]
Power On
Specify the state of power when the AC
power to the server is turn off once and
then on.
Platform Event
Filtering
Disabled
[Enabled]
Specify whether to enable or disable the
platform event filtering (PEF) feature.
[ ]: Factory-set
IMPORTANT:
To power on the server from the UPS (Uninterruptible
Power Supply), select [Server] - [AC LINK] - [Power On].
The table below shows the operation when the AC power to the server is turn off once and then on
again, depending on the setting of "AC LINK."
Setting of AC LINK
System status before AC power off
Stay Off
Last State
Power On
Operating
Off
On
On
Aborting (DC power being off also)
Off
Off
On
Forced shutdown
Off
Off
On
* Press the power switch continuously for four seconds or longer. This forcibly turns off the power.