General Description 2-9
STATUS Lamp
The STATUS lamp stays lit in green when the CPU blade is in successful operation. When the
STATUS lamp is flashing in amber or red, it indicates that the system has failed.
In addition, you can view the detailed information on error message on virtual LCD when the
STATUS lamp is flashing in amber or red.
You can use the virtual LCD through the Web browser of EXPRESSSCOPE engine (BMC) or NEC
ESMPRO Manager.
The following table lists indications of the STATUS lamp, descriptions, and actions to take.
If an error occurs, contact your service representative.
NOTE:
If the CPU blade has the NEC ESMPRO installed, you can
view the System Event Log (SEL) to identify the cause of a trouble.
STATUS lamp indications
STATUS lamp
Status
Color
Description
Action
On
Green
The CPU blade is operating
normally.
–
Off
–
The power is turned off.
Turn on the power.
On
Red
BMC is being initialized.
1. Wait until the lamp goes off.
2. If the lamp still goes on, check
installation of the CPU blade.
Flash
Red
See the table "Virtual LCD indications when STATUS lamp is flashing in
red" described later.
Flash
Amber
See the table "Virtual LCD indications when STATUS lamp is flashing in
amber" described later.
NOTE:
If the CPU blade is powered off while the STATUS lamp is
flashing in amber or red, the indication of the STATUS lamp is retained
except for certain factors. When the CPU blade is powered on, the
STATUS lamp goes on green (normal status).
Summary of Contents for N8400-086F
Page 14: ...viii This page is intentionally left blank...
Page 44: ...2 20 General Description This page is intentionally left blank...
Page 152: ...6 24 Installing and Using Utilities This page is intentionally left blank...
Page 158: ...7 6 Maintenance This page is intentionally left blank...
Page 218: ...A 2 Specifications This page is intentionally left blank...
Page 290: ...B 72 Installing the Operating System 4 Activate Windows The Windows activation is complete...