2-12 General Description
On-screen message
Description
Action
Location Error
In the Blade Enclosure, the
installation location of CPU blade
is incorrect, or the installation
locations of the fan and CPU
blade are incorrect. Thus, the
CPU blade failed to power on.
Refer to the User's Guide of Blade
Enclosure to check if the CPU blade is
installed in correct location.
Check the installation locations of the fan
and CPU blade.
If the same error persists, contact your
service representative.
Cooling Error
In the Blade Enclosure, the
number of fans installed is
insufficient or the installed fan is
faulty. Thus, the CPU blade failed
to power on due to insufficient
cooling power.
Proc1 Therm % 07
A high temperature warning was
detected in CPU #1.
Proc2 Therm % 07
A high temperature warning was
detected in CPU #2.
CPUx_DIMMyTemp07 A high temperature warning was
detected in DIMM.
x, y: Indicates location of DIMM
slot.
AmbientTempAlm07
A high temperature warning was
detected in CPU blade.
Check if the heat sink is installed
correctly on CPU blade.
Check if fans in Blade Enclosure work
normally.
Refer to the User’s Guide of the Blade
Enclosure to make sure that the
sufficient number of fans are installed in
correct locations.
Check if the fans and CPU blades are
installed in correct locations.
Check if the ambient temperature of
installation location satisfies the
operation guarantee condition.
If the same error persists, contact your
service representative.
AmbientTempAlm00
A low temperature warning was
detected in CPU blade.
Check if the ambient temperature of
installation location satisfies the
operation guarantee condition.
If the same error persists, contact your
service representative.
P1 VCCP Alm XX
P1 VTT Alm XX
P1 VDDQ Alm XX
P1 DDR_VTT AlmXX
P2 VCCP Alm XX
P2 VTT Alm XX
P2 VDDQ Alm XX
P2 DDR_VTT AlmXX
BB +1.1v Alm XX
BB +1.5v Alm XX
BB +1.8v Alm XX
BB +3.3v Alm XX
BB +5v Alm XX
BB +0.9vs Alm XX
BB +1.1vs Alm XX
BB +1.8vs Alm XX
BB +3.3vs Alm XX
BB +5vs Alm XX
BB +12vs Alm XX
Battery Alm XX
A voltage warning was detected
on CPU blade.
XX=07: Upper limit warning
XX=00: Lower limit warning
Contact your service representative.
Summary of Contents for N8400-086F
Page 14: ...viii This page is intentionally left blank...
Page 44: ...2 20 General Description This page is intentionally left blank...
Page 152: ...6 24 Installing and Using Utilities This page is intentionally left blank...
Page 158: ...7 6 Maintenance This page is intentionally left blank...
Page 218: ...A 2 Specifications This page is intentionally left blank...
Page 290: ...B 72 Installing the Operating System 4 Activate Windows The Windows activation is complete...