267
CHAPTER 16 STANDBY FUNCTION
Preliminary User’s Manual U16035EJ1V0UM
16.1.2 Standby function control register
The wait time after the STOP mode is cleared upon interrupt request is controlled with the oscillation stabilization
time select register (OSTS).
OSTS is set by an 8-bit memory manipulation instruction.
RESET input sets OSTS to 04H.
Figure 16-1. Format of Oscillation Stabilization Time Select Register (OSTS)
Address: FFFAH After reset: 04H R/W
Symbol
7
6
5
4
3
2
1
0
OSTS
0
0
0
0
0
OSTS2
OSTS1
OSTS0
OSTS2
OSTS1
OSTS0
Selection of oscillation stabilization time
0
0
0
2
12
/f
X
(488
µ
s)
0
0
1
2
14
/f
X
(1.95 ms)
0
1
0
2
15
/f
X
(3.91 ms)
0
1
1
2
16
/f
X
(7.81 ms)
1
0
0
2
17
/f
X
(15.6 ms)
Other than above
Setting prohibited
Caution The wait time after the STOP mode is cleared does not include the time (see “a” in the illustration
below) from STOP mode clear to clock oscillation start. The time is not included either by RESET
input or by interrupt request generation.
STOP mode clear
X1 pin voltage
waveform
V
SS
a
Remarks 1. f
X
: Main system clock oscillation frequency
2. Values in parentheses are for operation with f
X
= 8.38 MHz.