258
(4) Remote registers (RWr18 to RWr1F, RWr30 to RWr37)
Address
(RWr)
Item
Description
Default
CH1 CH2
18
19
30
31
Latch count value
(Latch counter input
terminal)
• This area stores the count value latched when the latch counter function by
latch counter input terminal is selected.
(For the overview of the operation, refer to Page 127, Section 8.5.)
• When Initial data setting request flag (RY9) is turned off then on, the value in
this area is cleared.
0
1A
1B
32
33
Measured frequency
value
• This area stores the frequency value measured when the frequency
measurement function is selected.
• When Initial data setting request flag (RY9) is turned off then on, the value in
this area is cleared.
0
Measured rotation
speed value
• This area stores the rotation speed value measured when the rotation speed
measurement function is selected.
• When Initial data setting request flag (RY9) is turned off then on, the value in
this area is cleared.
1C
1D
34
35
Measured pulse value
(Function input
terminal)
• This area stores the value of the ON width or OFF width of pulses input to
CH
Function input terminal (FUNC1, FUNC2) measured when the pulse
measurement function is selected.
• The following shows the range of values which can be stored.
0 to 2147483647 (increments of 0.1µs)
• When Initial data setting request flag (RY9) is turned off then on, the value in
this area is cleared.
0
1E
1F
36
37
Measured pulse value
(Latch counter input
terminal)
• This area stores the value of the ON width or OFF width of pulses input to
CH
Latch counter input terminal (LATCH1, LATCH2) measured when the
pulse measurement function is selected.
• The following shows the range of values which can be stored.
0 to 2147483647 (increments of 0.1µs)
• When Initial data setting request flag (RY9) is turned off then on, the value in
this area is cleared.
0