214
391
H
Moderate error
Cam switch
function, step
type setting
error (Output 1)
A value other than 0 and 1
is set in Cam switch
function, step type (Output
1) (address: 1500
H
).
indicates the channel
where settings are
incorrect.
*7 *3
Set Cam switch function, step
type (Output 1) (address:
1500
H
) to 0 or 1, and turn off
then on CH
Cam switch
execute command (RY26,
RY3E).
...
...
...
...
...
...
...
399
H
Moderate error
Cam switch
function, step
type setting
error (Output 9)
A value other than 0 and 1
is set in Cam switch
function, step type (Output
9) (address: 1900
H
).
indicates the channel
where settings are
incorrect.
*7 *3
Set Cam switch function, step
type (Output 9) (address:
1900
H
) to 0 or 1, and turn off
then on CH
Cam switch
execute command (RY26,
RY3E).
3A0
H
Moderate error
Cam switch
function, step
type setting
error (Output
10)
A value other than 0 and 1
is set in Cam switch
function, step type (Output
10) (address: 1980
H
).
indicates the channel
where settings are
incorrect.
*7 *3
Set Cam switch function, step
type (Output 10) (address:
1980
H
) to 0 or 1, and turn off
then on CH
Cam switch
execute command (RY26,
RY3E).
..
.
..
.
..
.
..
.
..
.
..
.
..
.
3A6
H
Moderate error
Cam switch
function, step
type setting
error (Output
16)
A value other than 0 and 1
is set in Cam switch
function, step type (Output
16) (address: 1C80
H
).
indicates the channel
where settings are
incorrect.
*7 *3
Set Cam switch function, step
type (Output 16) (address:
1C80
H
) to 0 or 1, and turn off
then on CH
Cam switch
execute command (RY26,
RY3E).
401
H
Moderate error
Cam switch
function, step
No. setting error
(Output 1)
The values set in Cam
switch function, step No.1
to No.16 setting (Output 1)
(address: 1502
H
to 1521
H
)
are not in the ascending
order.
indicates the channel
where settings are
incorrect.
*7 *3
Set Cam switch function, step
No.1 to No.16 setting (Output 1)
(address: 1502
H
to 1521
H
) to
values in the ascending order,
and turn off then on CH
Cam
switch execute command
(RY26, RY3E).
...
...
...
...
...
...
...
409
H
Moderate error
Cam switch
function, step
No. setting error
(Output 9)
The values set in Cam
switch function, step No.1
to No.16 setting (Output 9)
(address: 1902
H
to 1921
H
)
are not in the ascending
order.
indicates the channel
where settings are
incorrect.
*7 *3
Set Cam switch function, step
No.1 to No.16 setting (Output 9)
(address: 1902
H
to 1921
H
) to
values in the ascending order,
and turn off then on CH
Cam
switch execute command
(RY26, RY3E).
410
H
Moderate error
Cam switch
function, step
No. setting error
(Output 10)
The values set in Cam
switch function, step No.1
to No.16 setting (Output
10) (address: 1982
H
to
19A1
H
) are not in the
ascending order.
indicates the channel
where settings are
incorrect.
*7 *3
Set Cam switch function, step
No.1 to No.16 setting (Output
10) (address: 1982
H
to 19A1
H
)
to values in the ascending
order, and turn off then on CH
Cam switch execute command
(RY26, RY3E).
...
...
...
...
...
...
...
Error code
(hexadecimal)
Classification
Error name
Description and
cause
Operation of when an error
occurs
Action
Error CH
The other
CHs
Summary of Contents for NZ2GFCF-D62PD2
Page 1: ......
Page 2: ......
Page 54: ...52 Memo ...
Page 206: ...204 Memo ...
Page 303: ......
Page 304: ......