253
APPENDICES
A
Appendix 1 Details of R
emote I/O Signa
ls
Appendix 1.2 Details of r
emote outp
ut signals
RY2C
Update flag
reset command
(Measured
frequency
value)
• Turn on this signal to reset CH
Update flag (Measured frequency value) (RX2D,
RX45).
• When this signal is turned on, CH
Update flag (Measured frequency value)
(RX2D, RX45) turns off. After resetting is completed, CH
Update flag reset
completed (Measured frequency value) (RX2C, RX44) turns on.
(For the overview of the operation, refer to Page 236, Appendix 1.1.)
CH1
Update flag
reset command
(Measured
rotation speed
value)
• Turn on this signal to reset CH
Update flag (Measured rotation speed value)
(RX2D, RX45).
• When this signal is turned on, CH
Update flag (Measured rotation speed value)
(RX2D, RX45) turns off. After resetting is completed, CH
Update flag reset
completed (Measured rotation speed value) (RX2C, RX44) turns on.
(For the overview of the operation, refer to Page 236, Appendix 1.1.)
CH2
RY44
RY30
CH1
Pulse
measurement
start command
(Function input
terminal)
• Turn on this signal to start measuring pulses using CH
Function input terminal
(FUNC1, FUNC2).
• When this signal is turned on, the measurement of pulses using CH
Function
input terminal (FUNC1, FUNC2) starts. When the measurement starts, Operating
(1) is set in CH
Pulse measurement flag (Function input terminal) (RWr20.b6,
RWr38.b6).
RY48
CH2
RY31
CH1
Measured pulse
value update
flag reset
command
(Function input
terminal)
• Turn on this signal to reset CH
Measured pulse value update flag (Function
input terminal) (RX32, RX4A).
• When this signal is turned on, CH
Measured pulse value update flag (Function
input terminal) (RX32, RX4A) turns off. After resetting is completed, CH
Measured pulse value update flag reset completed (Function input terminal)
(RX31, RX49) turns on.
(For the overview of the operation, refer to Page 236, Appendix 1.1.)
RY49
CH2
RY32
CH1
Pulse
measurement
start command
(Latch counter
input terminal)
• Turn on this signal to start measuring pulses using CH
Latch counter input
terminal (LATCH1, LATCH2).
• When this signal is turned on, the measurement of pulses using CH
Latch
counter input terminal (LATCH1, LATCH2) starts. When the measurement starts,
Operating (1) is set in CH
Pulse measurement flag (Latch counter input
terminal) (RWr20.b7, RWr38.b7).
RY4A
CH2
RY33
CH1
Measured pulse
value update
flag reset
command
(Latch counter
input terminal)
• Turn on this signal to reset CH
Measured pulse value update flag (Latch counter
input terminal) (RX34, RX4C).
• When this signal is turned on, CH
Measured pulse value update flag (Latch
counter input terminal) (RX34, RX4C) turns off. After resetting is completed, CH
Measured pulse value update flag reset completed (Latch counter input terminal)
(RX33, RX4B) turns on.
(For the overview of the operation, refer to Page 236, Appendix 1.1.)
RY4B
CH2
RY35
CH1
ON width setting
change request
(PWM output)
• Turn on this signal to activate the changes of CH
ON width setting (PWM output)
(RWw1E to RWw1F, RWw36 to RWw37) during PWM output.
• When this signal is turned on, CH
ON width setting (PWM output) (RWw1E to
RWw1F, RWw36 to RWw37) is reflected to the high-speed counter module. After
the setting values are reflected, CH
ON width setting change completed (PWM
output) (RX35, RX4D) turns on.
(For the overview of the operation, refer to Page 236, Appendix 1.1.)
RY4D
CH2
RY36
CH1
Error reset
command
• Turn on this signal to reset CH
Latest error code (RWr22, RWr3A) and CH
Latest warning code (RWr23, RWr3B).
(For the overview of the operation, refer to Page 236, Appendix 1.1.)
RY4E
CH2
Remote
output
(RY) No.
Signal name
Operation
timing
Description
Summary of Contents for NZ2GFCF-D62PD2
Page 1: ......
Page 2: ......
Page 54: ...52 Memo ...
Page 206: ...204 Memo ...
Page 303: ......
Page 304: ......