CHAPTER 11 TROUBLESHOOTING
11
11.2 Er
ror
Code List
416
H
Moderate error
Cam switch
function, step
No. setting error
(Output 16)
The values set in Cam
switch function, step No.1
to No.16 setting (Output
16) (address: 1C82
H
to
1CA1
H
) are not in the
ascending order.
indicates the channel
where settings are
incorrect.
*7 *3
Set Cam switch function, step
No.1 to No.16 setting (Output
16) (address: 1C82
H
to 1CA1
H
)
to values in the ascending
order, and turn off then on CH
Cam switch execute command
(RY26, RY3E).
501
H
Moderate error
CH
Time unit
setting error
(Sampling
counter/
Periodic pulse
counter)
A value other than 0 and 1
is set in CH
Time unit
setting (Sampling
counter/Periodic pulse
counter) (RWw16,
RWw2E).
indicates the channel
where settings are
incorrect.
If the
parameters are
written with the
parameter
processing of
the slave
station, or Initial
data processing
completion flag
(RY8) or Initial
data setting
request flag
(RY9) is turned
off then on:
*13
If CH
Setting
change request
(Sampling
counter/Periodic
pulse counter)
(RY27, RY3F) is
turned off then
on:
*8
If the
parameters are
written with the
parameter
processing of
the slave
station, or Initial
data processing
completion flag
(RY8) or Initial
data setting
request flag
(RY9) is turned
off then on:
*13
If CH
Setting
change request
(Sampling
counter/Periodic
pulse counter)
(RY27, RY3F) is
turned off then
on:
*3
Set CH
Time unit setting
(Sampling counter/Periodic
pulse counter) (RWw16,
RWw2E) to 0 or 1, and perform
one of the following operations.
• If Initial data processing
request flag (RX8) is on, turn
off then on Initial data
processing completion flag
(RY8).
• If the parameters are written
with the parameter
processing of the slave
station, or Initial data setting
completion flag (RX9) is on,
turn off then on Initial data
setting request flag (RY9).
• If Initial data processing
request flag (RX8) and Initial
data setting completion flag
(RX9) are off, turn off then on
CH
Setting change request
(Sampling counter/Periodic
pulse counter) (RY27, RY3F).
502
H
Moderate error
CH
Cycle
setting error
(Sampling
counter/
Periodic pulse
counter)
CH
Cycle setting
(Sampling
counter/Periodic pulse
counter) (RWw17,
RWw2F) is set to 0.
indicates the channel
where settings are
incorrect.
If the
parameters are
written with the
parameter
processing of
the slave
station, or Initial
data processing
completion flag
(RY8) or Initial
data setting
request flag
(RY9) is turned
off then on:
*13
If CH
Setting
change request
(Sampling
counter/Periodic
pulse counter)
(RY27, RY3F) is
turned off then
on:
*8
If the
parameters are
written with the
parameter
processing of
the slave
station, or Initial
data processing
completion flag
(RY8) or Initial
data setting
request flag
(RY9) is turned
off then on:
*13
If CH
Setting
change request
(Sampling
counter/Periodic
pulse counter)
(RY27, RY3F) is
turned off then
on:
*3
Set CH
Cycle setting
(Sampling counter/Periodic
pulse counter) (RWw17,
RWw2F) to a value between 1
and 65535, and perform one of
the following operations.
• If Initial data processing
request flag (RX8) is on, turn
off then on Initial data
processing completion flag
(RY8).
• If the parameters are written
with the parameter
processing of the slave
station, or Initial data setting
completion flag (RX9) is on,
turn off then on Initial data
setting request flag (RY9).
• If Initial data processing
request flag (RX8) and Initial
data setting completion flag
(RX9) are off, turn off then on
CH
Setting change request
(Sampling counter/Periodic
pulse counter) (RY27, RY3F).
Error code
(hexadecimal)
Classification
Error name
Description and
cause
Operation of when an error
occurs
Action
Error CH
The other
CHs