1
14
-
'12 • P
A
C-T
-174
(b) Ceiling cassette-4 wa
y compact type (FDTC)
Models FDTC50VF
, 60VF
Control PCB
Power PCB
XR1
XR2
XR3
XR4
XR5
(
Remote operation input:volt-free contact
)
Option
1
2
3
4
5
6
+12
SW2
SW6
SW5
SW7
LED
・
2
LED
・
3
X
Y
1
3
X
Y
t°
Remote controller
TB2
WH
BK
CNW3
RD
CNW2
RD
CNW4
BL
CNW1
BL
CNB
WH
CNN
Y
CNH
BK
CNI
BL
CNT
BL
1
2
WH
RD
F200
(
3.15A
)
F201
(
3.15A
)
F202
(
1.0A
)
F203
(
0.16A
)
X4
5
3
CNW0
WH
7
TB1
CNJ
WH
(Operation)
(Heating)
(Compressor ON)
(Inspection)
Earth
Y
/
GN
Y
/
GN
Th
C
1
3
M
1
〜
CNR
WH
DM
WH BR
Y
Y
2
1
CNR2
BL
M
1 4 5 6 7
CNM
WH
FM
I
5 6 4 3 2
RD BL BR OR WH
RD BL BR OR WH
5 6 4 3 2
RD BL BR OR WH
CNM3
RD
CNM4
WH
BK
t°
BK
BK
t°
BK
1
2
1
2
BK
t°
BK
3
4
Th
I
-R2
Th
I
-R3
Th
I
-A
BL
BL
RD
RD
Y
Y
CNH2
WH
BK
t°
BK
5
6
Th
I
-R1
BK
BK
CNN2
BK
RD
RD
1
2
FS
WH
WH
CNI2
WH
3
4
5
6
7
8
9
10
1
2
1
2
3
4
5
6
1
2
1
2
BL
BL
RD
RD
Y
Y
BK
BK
WH
WH
CNC
WH
Power circuit
Y
/
GN
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
M
LM1
M
LM2
M
LM3
M
LM4
1
2
3
4
5
BK
BK
BK
BK
BK
CNJ2
WH
2
1
3
4
5
1
2
3
4
5
BL
BL
BL
BL
BL
1
2
3
4
5
RD
RD
RD
RD
RD
1
2
3
4
5
3
Power source line
Signal line
1 2
3
[
]
indoor unit and outdoor unit
Connecting line between
BL
1
Y
/
GN
Y
/
GN
Y
/
GN
6
7
8
9
BK
BK
BK
BK
10
BK
11
BK
12
BK
13
BK
14
BK
15
BK
16
BK
17
BK
BK
18
BK
19
BK
20
BK
1
2
3
4
5
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
I
FS
LM1
〜
4
DM
FM
Float switch
Drain motor
Fan motor
Louver motor
Indication lamp
(
Red-Inspection
)
Indication lamp
LED
・
3
F200
〜
203
Fuse
LED
・
2
Connector
CNB
〜
Z
(
Green-Normal operation
)
Model capacity setting
SW6
Operation check,Drain motor test run
SW7-1
SW5
Thermistor
(
Remote controller
)
Thermistor
(
Heat exchanger
)
Thermistor
(
Return air
)
Thc
Th
I
-R1,2,3
Th
I
-A
TB2
Terminal block
(
Signal line
)
(□
mark
)
Relay for DM
X4
■
mark
Closed-end connector
TB1
Terminal block
(
Power source
)
(□
mark
)
Remote controller communication
SW2
Orange
OR
BR Brown
BK Black
Blue
Color Marks
BL
Mark Color
Red
RD
Y
Y
/
GN
WH
Yellow
Yellow
/
Green
White
Plural units Master
/
Slave setting
address
Notes 1. indicates wiring on site.
3. See the wiring diagram of outside unit about the line between
4. Use twin core cable
(
0.3mm X2
)
at remote controller line. See spec
sheet of remote controller in case that the total length is more than 100m.
5. Do not put remote controller line alongside power source line.
2
inside unit and outside unit.
2. TB1 is the terminal block for heavy current
(
connecting line between
and TB2 is the terminal block for weak current
(
remote controller
)
.
indoor unit and outdoor unit
)
,
C
P
JA
0
0
3
Z
3
4
0
Summary of Contents for SRK100VNPZJX
Page 95: ... 94 12 PAC T 174 Models FDT100VF 125VF 140VF G H H H H A B F C D H G PJF000Z285 ...
Page 98: ... 97 12 PAC T 174 Models FDEN60VF 71VF C2 C1 A B F E G D B A C1 C2 C1 C2 PFA003Z817 B ...
Page 101: ... 100 12 PAC T 174 Models FDU200VF 250VF F F G B A C D E PJD001Z216 B ...
Page 113: ... 112 12 PAC T 174 b Wireless remote controller RCN E1R 60 17 150 Unit mm ...
Page 275: ... 274 12 PAC T 174 ...
Page 276: ... 275 12 PAC T 174 ...
Page 277: ... 276 12 PAC T 174 ...
Page 286: ... 285 12 PAC T 174 ...
Page 287: ... 286 12 PAC T 174 ...
Page 288: ... 287 12 PAC T 174 ...
Page 341: ... 340 12 PAC T 174 4GRNCEG VJG 2 Part number Power PCB Part number ...
Page 508: ... 507 12 PAC T 174 ...