-
503
-
'12 • PAC-T-174
Names of recommended signal wires
Terminal
block for
Super link
E board
Terminal
block for
iterface
Y
X
Y
X
DIP switch
(SW2-2)
●
XR
1~4
are for the DC 12V relay
●
XR
5
is a DC 12/24V or AC 220~240V relay
●
CNT connector (local) maker, model
Connector
Molex
5264-06
Molex
5263T
Terminals
DIP switch
(SW2-3)
DIP switch
(SW2-1)
Operation output
Output 1
Output 2
Output 3
Output 4
Input/
Output
Content
Function
Relay
ON/OFF
Output signal
Heating output
Compressor operation output
Malfunction output
XR
1
During air-conditioner operation
XR
2
During heating operation
XR
3
During compressor running
XR
4
ON
ON
ON
ON
During anomalous stop
Input
Input/
Output
Operation by
Remote Controller
Air-
Conditioner
Function
Setting
Setting
Content
SW2-1
SW2-3
Input signal
Level/Pulse XR
5
OFF
→
ON
ON
→
OFF
OFF
→
ON
ON
→
OFF
OFF
→
ON
OFF
→
ON
ON
OFF
OFF
OFF
OFF
→
ON
ON
→
OFF
ON
OFF
Allowed
Not allowed
Allowed
Not allowed
External input
Operation permission
Operation prohibition
External input
Operation permission
Operation prohibition
External
control
input
ON* Level input
OFF
ON*
OFF
ON*
OFF
Pulse input
Level
Level
Pulse
Shielded wire
Vinyl cabtyre round cord
Vinyl cabtyre round cable
Vinyl insulated wirevinyl sheathed cable for control
It is available to operate the air conditioning unit and to monitor the operation status with the external control unit (remote display)
by sending the input/output signal through CNT connector on the indoor control PCB.
Connection of super link E board
Functions of CNT connector
①
Switch ON the DIP switch SW2-2 (Factory setting: ON) on the interface PCB.
②
Wiring connection between the interface and the super link E board.
③
Clamp the connection cables with cable clamps.
Regarding the connection of super link E board, refer to the instruction manual of super link E board.
For electrical work, power supply for all of units in the super link system
must be turned OFF.
Caution:Wireless remote controller attached to the indoor unit can be used in parallel, after
connecting the wired remote controller. However, some of functions other than
the basic functions such as RUN/STOP, Temperature Setting, etc. may not work
properly and may have a mismatch between the display and the actual behavior.
No.
1
2
3
4
Within 200 m 0.5 mm
2
s
2 cores
Within 300 m 0.75 mm
2
s
2 cores
Within 400 m 1.25 mm
2
s
2 cores
Within 600 m 2.0 mm
2
s
2 cores
* Factory setting
Interface side
Super link E board
①
Connect a external remote control unit
(locally procured) to CNT terminal.
②
In case of the pulse input, switch OFF
the DIP switch SW2-1 on the interface
PCB.
③
When setting operation permission/
prohibition mode, switch OFF the DIP
switch SW2-3 on the interface PCB.
Indoor units
control box
Do not use the length over 2 meter
CNT
(Blue 6P)
Common
Output 1
Output 2
Output 3
Output 4
Remote start / stop button or timer point
Butt splice
(Application coverage
0.75
~
1.25mm
2
)
Remote start/stop kit
0.75mm
2
×
2m
Note (1) 0.3mm
2
×
2m
Red
Blac
Yellow
Blue
Brown
Orange
White
Black
Yellow
Blue
Brown
Orange
Orange
Input
power
+12
PCB (Printed Circuit Board)
XR1
XR1
XR2
XR3
XR4
XR2
XR3
XR4
XR5
1 1
2 2
3 3
4 4
5 5
6 6
Summary of Contents for SRK100VNPZJX
Page 95: ... 94 12 PAC T 174 Models FDT100VF 125VF 140VF G H H H H A B F C D H G PJF000Z285 ...
Page 98: ... 97 12 PAC T 174 Models FDEN60VF 71VF C2 C1 A B F E G D B A C1 C2 C1 C2 PFA003Z817 B ...
Page 101: ... 100 12 PAC T 174 Models FDU200VF 250VF F F G B A C D E PJD001Z216 B ...
Page 113: ... 112 12 PAC T 174 b Wireless remote controller RCN E1R 60 17 150 Unit mm ...
Page 275: ... 274 12 PAC T 174 ...
Page 276: ... 275 12 PAC T 174 ...
Page 277: ... 276 12 PAC T 174 ...
Page 286: ... 285 12 PAC T 174 ...
Page 287: ... 286 12 PAC T 174 ...
Page 288: ... 287 12 PAC T 174 ...
Page 341: ... 340 12 PAC T 174 4GRNCEG VJG 2 Part number Power PCB Part number ...
Page 508: ... 507 12 PAC T 174 ...