background image

Air Scrubber Owner's Manual

Model:

X-2000 Series / X-3000 Series / X-4000 Series

(115 V~60HZ)

Read and save these instructions before use

www.xpower.com | 1-(855)-855-8868 | [email protected]

Index: NA-1-A7

Edition: 3.0.Alpha

Summary of Contents for X-2000 Series

Page 1: ... Scrubber Owner s Manual Model X 2000 Series X 3000 Series X 4000 Series 115 V 60HZ Read and save these instructions before use www xpower com 1 855 855 8868 info xpower com Index NA 1 A7 Edition 3 0 Alpha ...

Page 2: ... X 4700AM Suitable for use with solid state speed control DO NOT touch this appliance or the plug with wet hands or while standing in water DO NOT operate the appliance in any pooled water DO NOT use the product in areas where gasoline paint or other flammable goods and objects are used or stored DO NOT insert or allow objects to enter any ventilation or exhaust opening as this may damage the appl...

Page 3: ...ar la unidad Lire et conserver ces instructions avant utilisation www xpower com 1 855 8868 info xpower com Index NA 1 A2 Edition 1 0 Alpha Owner s Manual x 1 Air Scrubber x 1 1 Rubber Feet 2 Latch Kit 3 Cover 4 Foam Cover 5 Additional Electrical Receptacle 6 Switch Plate 7 Front Housing 8 Motor Assembly 9 Air Outlet Grille 10 Motor Holder 11 Pressure Switch 12 Rear Housing 13 Capacitor 14 Power C...

Page 4: ...al Specifications If your product s is not listed above please visit www xpower com for more information Nylon Mesh Filter Carbon Filter HEPA Filter Washable Filter Outer Nylon Mesh Filter NFR9 NFR12 NFS13 NFS16 PF13 PF16 CF15 CF35 HEPA35 HEPA35 33 HEPA50 WF35 WF35 EVA WF50 Pleated Media Filter MODEL NUMBER X 2380 X 2580 X 2480A X 3380 X 3580 X 3780 X 3400A X 4700A X 4700AM First Stage Filter NFR9...

Page 5: ... circulation inside your working area You may achieve this with XPOWER Air Mover combinations Environment Humidity For optimal efficiency and higher filter lifespan the Air Scrubber should not be operated in an environment with a high relative humidity level High humidity level could cause blockage and damage to filters Power Cord The power cord has a length of 13 feet 4 0 meters Select a location...

Page 6: ...ing Turn off the machine and remove the outer nylon mesh filter and foam cover Attach the ducting hose to the intake For model X 2380 X 2580 X 3380 X 3580 only For model X 2480A X 3400A X 4700A X 4700AM only Exhaust Ducting Turn off the machine Attach the ducting hose to the exhaust ...

Page 7: ...X 3400A X 4700A X 4700AM only Turn to OFF position to switch the Air Scrubber OFF Turn to any speed position to switch the Air Scrubber ON Turn clockwise to set the desired speed MAX means the highest speed and LOW means the lowest speed Five Speed Control For Model X 2380 X 2480A X 2580 X 3380 X 3580 X 3780 Turn to OFF position to switch the Air Scrubber OFF Turn to any speed position to switch t...

Page 8: ...00A X 4700A X 4700AM only Foam Cover Time Meter For Model X 4700AM Only The time meter shows the total running time from the first usage to the current moment When the machine turns on the activity indicator will blink The running time starts to count When the machine is off the activity indicator will stay illuminated The value can t be reset When the value exceeds 9999 9 hours it will start over...

Page 9: ... electrical receptacle Once a ground fault occurs the GFCI will immediately interrupt the power connection to the additional electrical receptacle Consult the Troubleshooting Guide A ground fault is an inadvertent contact between an energized conductor for example a human being and ground or equipment frame WARNING Risk of electric shock You should test the GFCI before each use Press the Test Butt...

Page 10: ...e with the foam cover See Also Page 8 Foam Cover Store the appliance in a dry and cool indoor place Make sure it s out of reach of children Use a damp cloth to wipe the surface of the housing Do not clean the unit with water directly Check if the grille covers are clean Remove dirt or any other objects that could block the air inlet and air outlet Do not stack more than five units of this applianc...

Page 11: ...e follow the instructions below Continued Machine Maintenance Continued Outer Nylon Mesh Filter Organize the Cord Wrap the power cord around the intake for storage after use Use convenient clip at end of cord to secure in place Wrap around design does not apply to all models mentioned in this manual Outter Nylon Mesh Filter Outer nylon mesh filter is on the intake of the Air Scrubber Take out this...

Page 12: ...lp remove various substance absorbed in the carbon with an appropriate temperature If filter change light still illuminates or a decline of effectiveness is noted you might need to replace the filter HEPA Filters This filter is not washable or reusable Highly concentrated particles are captured by the HEPA filter and cleaning this filter can be hazardous to human health and contaminate the nearby ...

Page 13: ... check the installation sequence WARNING DISPOSAL OF FILTERS NO LONGER IN USE The particles captured by a used filter can cause adverse human health effects and contaminate the nearby environment once the filter is exposed to the open air Adequate personal protection equipment PPE is required during the whole process for example industry approved masks eye protectors gloves and coveralls You shoul...

Page 14: ... be loaded with EVA side facing the machine housing The EVA sealing pad ensures that all the air is filtered Tips On one of the side of each filter there is a label with an arrow showing the airflow direction When placing the filter the side with label should face up The arrow on the label should point to the blue housing EVA Housing Former Stage Filters Airflow Direction ...

Page 15: ...ips Remove all appliances on the additional electrical receptacle and press circuit reset button Unit runs but no or very low air movement Air outlet is blocked Remove blockage Filters are fully loaded The filter change light illuminates Clean or replace the loaded filters See Page 11 Filter Maintenance The additional electrical receptacle has no power The circuit breaker on the additional electri...

Page 16: ... 2 GFCI Outlets Time Meter N A Yes Cord Length 13 ft 4 m Unit Dimension L x W x H 16 6 x 10 4 x 18 9 in 42 2 x 26 4 x 48 cm 19 6 x 12 3 x 21 6 in 49 8 x 31 2 x 54 9 cm 18 5 x 12 3 x 21 6 in 47 0 x 31 2 x 54 9 cm 19 6 x 12 3 x 21 6 in 49 8 x 31 2 x 54 9 cm Unit Weight 23 0 lbs 10 4 kg 23 6 lbs 10 7 kg 30 5 lbs 13 8 kg 32 8 lbs 14 9 kg 32 2 lbs 14 6 kg 28 8 lbs 13 1 kg 33 1 lbs 15 0 kg Safety Certif...

Page 17: ...ation for fine dust PF16 16 x 16 in 0 8 in CF15 Carbon Filter 13 x 13 in 0 6 in Filtration for gases CF35 16 x 16 in 1 4 in WF35 Washable Filter 13 x 13 in 1 3 in Medium filtration for fine dust and particles WF35 EVA 16 x 16 in 1 5 in WF50 13 x 13 in 2 0 in HEPA35 33 HEPA High Efficiency Particulate Air Filter 13 x 13 in 1 4 in Final filtration for micro particles HEPA35 16 x 16 in 1 5 in HEPA50 ...

Page 18: ...istance from XPOWER please 1 Email info xpower com 2 Call XPOWER U S Customer Service Department at 855 855 8868 or other numbers provided on www xpower com 3 Visit XPOWER U S Head Office at 668 S 6th Ave City of Industry CA 91746 or the most current address provided on www xpower com Please also have your original proof of purchase and the serial number s of your product s ready when you contact ...

Page 19: ...o the address provided by XPOWER with the RMA number on the shipping label or the packaging 3 Include all the original parts and components XPOWER will inspect assess and advise the repairs needed and applicable cost if any For products under warranty we will pay to ship the repaired or replaced product s to you if you use an address within the Contiguous United States Otherwise we will ship the p...

Page 20: ...Read and save these instructions before use www xpower com 1 855 855 8868 info xpower com 668 S 6th Avenue City of Industry CA 91746 USA Index NA 1 A7 Edition 3 0 Alpha XPOWER Manufacture INC ...

Reviews: