6.5.4 Station to station test
In the station to station test, the hardware of the MELSECNET/H board, network
modules and cables between two adjacent stations can be checked.
The following explains how to conduct the station to station test:
REMARK
This section explains concerning the MELSECNET/H board.
Refer to the following manuals concerning network module settings.
• Q corresponding MELSECNET/H Network System Reference Manual (PLC to
PLC network)
• QnA/Q4AR Corresponding MELSECNET/10 Network System Reference Manual
(1) Connecting the cable
(a) Optical loop system
Connect IN and OUT of network modules, Q80BD-J71LP21-25, Q81BD-
J71LP21-25, Q80BD-J71LP21S-25, Q80BD-J71LP21G or Q80BD-
J71LP21GE with an optical fiber cable.
Side
Station
No. n
Optical fiber cable
Station to
execute test
IN
OUT
Station to
be tested
Side
Station
No. n+1
IN
OUT
(b) Coaxial bus system
Connect network modules or Q80BD-J71BR11 with a coaxial cable.
Terminal
resistor
Coaxial cable
Side
Station
No. n
Station to
be tested
Side
Station
No. n+1
Station to
execute test
Terminal
resistor
Summary of Contents for Q80BD-J71BR11
Page 2: ......
Page 24: ...A 22 A 22 MEMO ...
Page 50: ...4 6 4 6 MELSEC 4 FUNCTION MEMO ...
Page 92: ...6 36 6 36 MELSEC 6 PROCEDURE AND SETTINGS UP TO THE POINT OF OPERATION MEMO ...
Page 132: ...10 2 10 2 MELSEC 10 MELSEC DATA LINK LIBRARY MEMO 10 ...
Page 138: ...11 6 11 6 MELSEC 11 PROGRAMMING MEMO ...
Page 164: ...12 26 12 26 MELSEC 12 APPLICATION FUNCTIONS MEMO ...
Page 166: ...13 2 13 2 MELSEC 13 ERROR CODE MEMO 13 ...
Page 223: ......