14 - 4
14 - 4
MELSEC
14 TROUBLESHOOTING
No.
Error detail
Cause determination method/Corrective action
11
CPU modules other than QCPU cannot be accessed.
CPU modules other than QCPU (Q mode) cannot be
accessed to the 64-bit version of user application. Use
32-bit version of user application.
12
The utility screen is not displayed properly.
The operations of utility cannot be performed.
1) Check if the display settings on the [Device
Manager] or other relevant functions are correct,
and install an appropriate display driver.
Or update the Windows
R
operating system.
2) Close the other applications.
3) Change the Hardware accelerator setting of the
display setting.
13
When transmitting the data using SEND function of
mdSend function, the transmission is completed
normally, however, the data is not received at the
destination.
Refer to section 12.3.4.
14
The driver does not start up.
1) Install the board.
2) Check if the board is recognized normally on the
"Device Manager" screen. (Refer to Section 14.3.3)
3) When the board is recognized normally on the
Device Manager screen, check if an error has
been occurred on the Event Viewer screen. (Refer
to Section 14.3.2)
Summary of Contents for Q80BD-J71BR11
Page 2: ......
Page 24: ...A 22 A 22 MEMO ...
Page 50: ...4 6 4 6 MELSEC 4 FUNCTION MEMO ...
Page 92: ...6 36 6 36 MELSEC 6 PROCEDURE AND SETTINGS UP TO THE POINT OF OPERATION MEMO ...
Page 132: ...10 2 10 2 MELSEC 10 MELSEC DATA LINK LIBRARY MEMO 10 ...
Page 138: ...11 6 11 6 MELSEC 11 PROGRAMMING MEMO ...
Page 164: ...12 26 12 26 MELSEC 12 APPLICATION FUNCTIONS MEMO ...
Page 166: ...13 2 13 2 MELSEC 13 ERROR CODE MEMO 13 ...
Page 223: ......