6 - 32 6 - 32
MELSEC
6 PROCEDURE AND SETTINGS UP TO THE POINT OF OPERATION
REMARK
Before conducting the station to station test when three or more stations are
connected by the coaxial bus system, any stations that are not tested should be
switched to offline or powered off.
Offline or
powered off
Station to
be tested
Station to
execute test
(2) Test mode settings
In the mode settings in the MNETH utility's "Board Information" screen, set the
Station No. n, Station No. n + 1 stations' respective "Test between master
station" and "Test between slave station" settings.
(3) Start of inter-station test
Set the mode setting on "Test between master station" or "Test between slave
station" and click the Board Set button.
This operation is performed in the order of control station normal station.