IX
Troubleshooting ]
- 117 -
HWE10060
GB
*Preliminary error codes will not appear on the 7-segment LED.
Error Type
Cause
(problem with the installation
environment/setting error)
Cause
(component problem)
Error Code
Circuit board
Remote controller
Resetting the error
Unit side
board)
(Circuit
Remote
SWS1
Operation SW
Power supply fault
Active filter fault
Heat exchanger freeze up
Discharge temperature fault
*8
*7
4106
(Details : 255)
4121
(Preliminary : 4171)
AC61
(Preliminary AC71)
1104
Current-related problem
during normal operation
IPM error
4250
4255
(Preliminary : 4350)
(Preliminary : 4355)
(Details :
101)
4250
4255
(Preliminary : 4350)
(Preliminary : 4355)
(Details :
102)
4250
4255
(Preliminary : 4350)
(Preliminary : 4355)
(Details :
103)
4250
4255
(Preliminary : 4350)
(Preliminary : 4355)
(Details :
107)
●After a power reset, if nomal power suppy is not detected five consecutive times at 20
ms intervals,this will be regarded as an error.
●A suction temperature of -2ºC or below has been detected for 10 seconds during the
defrost cycle and 30 seconds after the initiation of the defrost cycle.
●Incorrect dip switch setting
●Incorrect SW2-4 setting
●Transmission power supply output fault
Wiring fault
Detection of overcurrent in the transmission power supply
●Transmission power supply power reception fault
In a multiple unit system, one unit started supplying power,
but the other units have not.
Transmission power supply fault
Transmission voltage detection circuit fault
●4-way valve switching failure
●High-pressure sensor fault
●Discharge refrigerant thermistor fault
●Linear expansion valve fault (Main circuit LEV, injection LEV)
●Injection solenoid valve fault
●Fan motor error
●Fan inverter fault
●Refrigerant shortage (gas leakage)
●Thermistor input circuit fault on the control board
●INV board fault
●Ground fault of the compressor or fan motor
●Coil fault on the compressor or fan motor
●IPM fault (loose terminal screws, cracks due to swelling)
●Items in the "Heatsink overheat protection" row in the
"Cause" column.
●INV board fault
●Compressor ground fault
●Coil failure
●IPM fault (loose terminal screws, cracks due to swelling)
●Water depletion
●Abrupt water temperature change
(5K/min or greater)
●Pump fault
●Drop in water flow or water outage
during defrost
●
Water temperature drop during defrost
●30 seconds after the compressor has
started up
●An overcurrent was detected by the
overcurrent detection resistor (RSH) on
the INV board.
●An IPM error signal was detected.
ACCT overcurrent
●30 seconds after the compressor has
started up
●A peak current of at or above 56A or 33
Arms was detected by the current sensor.
DCCT overcurrent
●30 seconds after the compressor has
started up
●A peak current of at or above 56A or 33
Arms was detected by the current sensor.
Overcurrent relay trip (effective value)
(During normal operation)
●30 seconds after the compressor has
started up
●A current of at or adove 33 Arms was
detected by the current sensor.
●Preliminary : A discharge temperature of 120ºC or above has been detected for 30
seconds while the compressor is in operation.
●Error : The above preliminary error was detected three times.
●Error : A discharge temperature of 125ºC or above was detected momentarily.
Inverter fault
Summary of Contents for CAHV-P500YA-HPB
Page 1: ...Service Handbook Service Handbook CAHV P500YA HPB Model 2011 HOT WATER HEAT PUMP ...
Page 7: ...CONTENTS HWE10060 GB ...
Page 9: ... 2 HWE10060 GB ...
Page 19: ... 12 HWE10060 GB ...
Page 37: ... 30 HWE10060 GB ...
Page 46: ... 39 HWE10060 GB IV Remote Controller 1 Using the Remote Controller 41 2 Function Settings 46 ...
Page 47: ... 40 HWE10060 GB ...
Page 55: ... IV Remote Controller 48 HWE10060 GB ...
Page 56: ... 49 HWE10060 GB V Electrical Wiring Diagram 1 Electrical Wiring Diagram 51 ...
Page 57: ... 50 HWE10060 GB ...
Page 61: ... V Electrical Wiring Diagram 54 HWE10060 GB ...
Page 63: ... 56 HWE10060 GB ...
Page 67: ... VI Refrigerant Circuit 60 HWE10060 GB ...
Page 69: ... 62 HWE10060 GB ...
Page 101: ... VII Control 94 HWE10060 GB ...
Page 103: ... 96 HWE10060 GB ...
Page 109: ... VIII Test Run Mode 102 HWE10060 GB ...
Page 111: ... 104 HWE10060 GB ...
Page 155: ... IX Troubleshooting 148 HWE10060 GB ...
Page 156: ... 149 HWE10060 GB X Attachments 1 R407C saturation temperature table 151 ...
Page 157: ... 150 HWE10060 GB ...
Page 159: ... X Attachments 152 HWE10060 GB ...