SUPERSET Interface Module 2
The SUPERSET nterface Module (SIM2) allows the connection of one Mitel Networks 5410
Programmable Key Module or up to two Mitel Networks 5415 Programmable key Modules and
one two-wire analog device such as an analog telephone, fax machine, or modem (to a
maximum loop length of 50 feet and a ringer load of up to 2 REN). This interface module allows
simultaneous use of both the SUPERSET 4000 series telephone and the analog peripheral.
The SUPERSET 4025 and the SUPERSET 4125 telephone require a power adaptor for the
interface module connection. A power adaptor comes with the SUPERSET 4150 telephone but
must be ordered if the PKM 48 or PKM 12 is to go on a SUPERSET 4025 or a SUPERSET
4125 telephone.
Message Waiting is not supported by sets connected to a SIM2. Devices with a Z-type REN
are not to be connected to a SIM2. The analog device must signal using DTMF tones; devices
that use dial pulse signaling are not supported.
SUPERSET Interface Module 2 in a SUPERSET 4150 Telephone