Configuration
50003510
Revision A
43
•
Calls do not have to be evenly distributed across all bays
•
Maximum channel blocking ratio is 0.94.
Connecting SX-200 IP Nodes
You can connect up to two SX-200 IP Nodes to the SX-200 EL. The system requires one Control
Triple CIM card (three onboard CIM circuits) in the main control cabinet.
The following connections are required to configure the SX-200 IP Node:
•
Connections between peripheral bays and the main control cabinet are made with standard
CIM connections, page 41.
•
An Ethernet crossover cable connects the Control Triple CIM Card in the main control
cabinet to the CIM port on the IP Node. All voice and signalling communications are carried
over this connection.
•
Another Ethernet crossover cable connects the IP Node to the Ethernet switch on the LAN.
•
The IP phones are connected to the LAN through the Ethernet switch.
The configuration rules that apply to connecting standard peripheral bays to the control cabinet
through CIMs also apply to connecting IP Nodes. For more information about configuration,
see the Configuration Rules for the
•
SX-200 EL Control Cabinet
•
Bays supported by the SX-200 EL System
Summary of Contents for SX-2000 EL
Page 1: ...GENERAL INFORMATION GUIDE LIGHTWARE 19 RELEASE 3 1 ...
Page 14: ...xiv Revision A 50003510 SX 200 General Information Guide ...
Page 34: ...SX 200 General Information Guide 20 Revision A 50003510 ...
Page 61: ...Configuration 50003510 Revision A 47 SX 200 ML Configuration Example ...
Page 114: ...SX 200 General Information Guide 100 Revision A 50003510 ...
Page 214: ...SX 200 General Information Guide 200 Revision A 50003510 ...
Page 226: ...SX 200 General Information Guide 212 Revision A 50003510 ...
Page 257: ...Glossary of Terms 50003510 Revision A 243 NOTES ...