SX-200 General Information Guide
38
Revision A
50003510
Bay Power Supply
- provides required voltages to peripheral cards, control cards, PRI cards,
and system peripheral devices.
CAUTION:Do not install more than one PRI card in the control cabinet. This restriction
allows the bay to be within the power budget.
Control Dual FIM Carrier Card
- supports two Fiber Interface Modules and connects to the
backplane. The card distributes 6 links to two bays: 3 links per bay. One 1 km FIM is onboard
the Control Dual FIM Carrier card. A connector is on the card for an additional FIM.
Control Triple FIM Carrier Card MM 1 km
- supports up to three Fiber Interface Modules and
connects them to the backplane. With a MCCIIIEL card, the Control Triple FIM card distributes
6 links to three bays: 2 links per bay. With a MCCIIIELx card, the Control Triple FIM card
distributes 9 links to three bays: 3 links per bay. It has two 1 km FIMs onboard and a connector
to plug in a third optional FIM (either a 1 km FIM or an extended FIM).
Control Triple FIM Carrier Card MM 5km
- similar to the Control Triple FIM Carrier Card with
the exception that this card has two muti-mode 5 km FIMs onboard and a connector to plug in
a third optional FIM (either a 1 km FIM or an extended FIM).
Control Triple FIM Carrier Card SM 14km
- similar to the Control Triple FIM Carrier Card with
the exception that this card has two single mode 14 km FIMs onboard and a connector to plug
in a third optional FIM (either a 1 km FIM or an extended FIM).
Fiber Interface Module (FIM)
- supports the transmission of voice and data signals over fiber
optic cables. The FIM plugs into the Control FIM Carrier. Three Fiber Interface Modules are
available with ranges of 1 km, 5 km, and 14 km. Both FIMs at each end of a fiber cable must
be the same type. Onboard FIMs in the Control Dual FIM Carrier, Control Module II, and
Application Fiber Controller (AFC) card are 1 km FIMs. Add on FIMs are ordered separately.
Control Triple CIM Card
- provides three onboard Copper Interface Module (CIM) circuits.
The card also has a connector for a FIM II so that a FIM II may be used in place of one of the
CIM circuits. The card may be used for an SX-200 EL system or an SX-200 ML system. A
manual switch determines whether the card emulates a Dual or Triple FIM Carrier card. Any
SX-200 rack-mount cabinet supports the Control Triple CIM Card.
Copper Interface Module (CIM)
- supports the transmission of voice and data signals over
copper cables that provide connectivity between the main control cabinet and the peripheral
cabinets. The CIM uses a twisted pair interface with standard Category 5 cable. The CIM is
similar to the FIM in the way that it provides 3 ST links. In a main control cabinet, the CIM plugs
onto the PRI card. In a peripheral cabinet, the CIM plugs onto the BCC III, Peripheral Interface
Module Carrier card, or the PRI card. The CIM supports connectivity of cabinets up to 30 meters
or 100 feet apart. The copper interface modules are ideal for a co-located system.
FIM II
- supports the transmission of voice and data signals over fiber optic cables that provide
connectivity between the main control cabinet and the peripheral cabinets. The FIM II plugs
into the PRI card, the BCC III, Peripheral Interface Module Carrier card, or the Control Triple
Summary of Contents for SX-2000 EL
Page 1: ...GENERAL INFORMATION GUIDE LIGHTWARE 19 RELEASE 3 1 ...
Page 14: ...xiv Revision A 50003510 SX 200 General Information Guide ...
Page 34: ...SX 200 General Information Guide 20 Revision A 50003510 ...
Page 61: ...Configuration 50003510 Revision A 47 SX 200 ML Configuration Example ...
Page 114: ...SX 200 General Information Guide 100 Revision A 50003510 ...
Page 214: ...SX 200 General Information Guide 200 Revision A 50003510 ...
Page 226: ...SX 200 General Information Guide 212 Revision A 50003510 ...
Page 257: ...Glossary of Terms 50003510 Revision A 243 NOTES ...