15 Appendix
Group 81: IRQ_4_5
81-4
Time overflow low-level
IRQ
Please contact the Technical Support team.
Group 82: Internal sequence control
82-0
Sequence control
Internal sequence control: The process was
aborted.
For information only. No measures required.
82-1
Concurrent CO write
access
Please contact the Technical Support team.
Group 83: Technology modules
83-0
Technology module:
slot/combination
The technology module cannot be used in the
current slot or the combination of technology
modules is not permissible.
Contact the Technical Support team.
83-1
Technology module not
supported
Load the most recent firmware.
83-2
Technology module:
HW revision not
supported
Load the most recent firmware.
83-3
Service module: write
error
Please contact the Technical Support team.
83-4
MC2000 Watchdog
Please contact the Technical Support team.
Group 84: Internal sequence control
84-0
Conditions for controller
enable not fulfilled
Enable the servo drive again after a short period
of time. If the error recurs, check the following:
- Are there still errors?
- Is the angle encoder ready?
- Has DIN4 been set?
- Is MOTID still being executed?
- Is there a running TFTP download?
- Has an energy-saving mode been activated via
PROFIenergy?
- Does the FSM 2.0 – MOV (SBC) block the
enable signal?
Product manual BL 4000-C