4 Quick-start guide
4.4
Software-guided commissioning
Risk of damage to the servo drive and motor
Perform the fundamental adjustment steps in the proper sequence as described in the
manual. This is to prevent the motor and/or servo drive from being damaged beyond
repair.
The commissioning process is a feature to help non-expert users with the initial start-up of
the motor/drive. The user is guided through several dialogue-based menus. Some of these
menus use automatic identification mechanisms of the servo drive.
The commissioning of the servo drive can be performed after the correct installation of the
Metronix ServoCommander
®
parameterisation program and the setup of a communication
connection to the servo drive. In addition, the servo drive should be completely connected
and the supply with mains power should be possible. Follow the instructions concerning
the correct installation of the servo drive in section 13.1
You can also start the commissioning process for a servo drive that is already in use. To
do so, select the menu item
File/Commissioning
. It is also possible to load a suitable
preset parameter set.
Status "not commissioned"
When it is delivered, the servo drive has the status "not commissioned". In this case,
the 7-segment display shows the letter "A". As soon as one of the windows relevant for
the commissioning process (e.g. the menu
Angle encoder settings
) is opened and a
value is changed, the letter "A" will disappear.
Figure 8: "Commissioning" windows
Complete performance of the commissioning process
Even if a parameter set has been loaded, perform the entire commissioning process to
verify the settings.
Take your time. Ensure that you have properly understood and configured everything.
The following sections describe the individual windows of the commissioning process in
detail.
Product manual BL 4000-C