7 Additional settings
7.7.1
Configuration of the digital inputs
Parameters/IOs/Digital inputs
The servo drives have numerous functions that can be triggered via the digital inputs.
Some of these functions are assigned to special digital inputs in a fixed manner. The other
functions can be assigned to the other digital inputs as required by the specific application.
For some of the functions, the digital inputs must fulfil special requirements so that not all
of the available digital inputs can be used for all of the functions.
In general, a function can be assigned clearly to only one digital input. This means that it is
not possible to activate the same function via two different digital inputs. However, it is
possible to trigger two functions simultaneously via the same digital input. In this case,
the user must ensure that no conflict ensues.
Figure 98: "Digital inputs" window
Position selector
To address a target position based on the 256 programmable targets, a position selector
can be configured. In addition, a start input and a sample input can be used for the
positioning process.
Jog mode
The input to be used for the negative or positive direction of rotation can be specified for
the jog mode.
Digital stop
The "Digital stop" stop signal affects the positioning and speed control process.
Product manual BL 4000-C