13 Electrical installation
13.1.4
Operation with long motor cables
Compliance with the EMC standard EN 61800-3
Compliance with the EMC standard EN 61800-3 is ensured only for a motor cable length
of 25 m maximum.
Operation with longer cables is not permissible.
In applications involving long motor cables and/or in the case of unsuitable motor cables
with a non-permissible high cable capacity, the filters, power output stage and sensors
may be overloaded.
In applications involving long motor cables and/or in the case of unsuitable motor cables
with a non-permissible high cable capacity, the filters, power output stage and sensors
may be overloaded.
13.1.5
ESD protection
Damage to property due to ESD (electrostatic discharge)
At unassigned plug connectors, damage can occur to the device or to other system parts
as a result of ESD (electrostatic discharge).
To prevent this type of damage, comply with the following:
l
Ensure proper earthing of all of the system components and wire the servo drive
completely prior to switching on the voltage supply.
l
The person commissioning the system as well as the service and maintenance
personnel must have undergone ESD training and wear corresponding footwear.
l
When handling the system, e.g. the USB connector, it is useful to touch the
control cabinet housing (should be at PE potential) with your hand prior to
touching one of the connectors of the servo drive.
Product manual BL 4000-C
Page 237 of 298