MI 3101 EurotestAT:
Technical specifications
95
Voltage drop (calculated value)
Measuring range (%)
Resolution (%)
Accuracy
0.0
99.9
0.1
Consider accuracy of line
impedance measurement
Z
REF
measuring range……………………… 0.00
Ω
20.0
Ω
8.6 Voltage, frequency, and phase rotation
8.6.1 Phase rotation
Nominal system voltage range.......... 100 V
AC
550 V
AC
Nominal frequency range.................. 14 Hz
500 Hz
Result displayed ............................... 1.2.3 or 3.2.1
8.6.2 Voltage
Measuring range (V)
Resolution (V)
Accuracy
0
550
1
(2 % of r 2 digits)
Result type........................................ True r.m.s. (trms)
Nominal frequency range.................. 0 Hz, 14 Hz
500 Hz
8.6.3 Frequency
Measuring range (Hz)
Resolution (Hz)
Accuracy
0.00
999.99
0.01
(0.2 % of r 1 digit)
Nominal voltage range ...................... 10 V
550 V
8.7 Online terminal voltage monitor
Measuring range (V)
Resolution (V)
Accuracy
10
550
1
(2 % of r 2 digits)
8.8 Earth resistance
Earth
resistance three-wire method
Measuring range according to EN61557 is 0.67
9999
Measuring range (
)
Resolution (
)
Accuracy
0.00
19.99
0.01
20.0
199.9
0.1
(3 % of r 3 digits)
200
1999
1
5 % of reading
2000
9999
1
10 % of reading
Additional spike resistance error if
Rc max. or Rp max. is exceeded ......
(5 % of r 10 digits)
Rc max. ............................................ 100 R
E
or 50 k
(whichever is lower)