MI 3101 EurotestAT: Data handling
Clearing saved data
83
6.5 Clearing saved data
From main menu select miscellaneous menu and enter
option (see
4.4.3
).
In
select
option for erasing complete test
results memory.
Figure 6.11: Clear memory
Keys:
/
Select CANCEL / CLEAR.
TEST
Confirms selected option.
ESC
Cancels dialog without changes.
In
select
option to delete particular result
or modify installation data structure.
Figure 6.12: Clear test menu
Keys:
/
Select
location.
TEST
Opens dialog for clearing in installation data structure.
TAB
Moves focus into result field for selection of surplus result, see
6.5.1
.
F2
Enters installation structure tree view to select appropriate location.
F1
Renames current location.
ESC
Back to the last mode of the instrument.