Description of Functions
Function
Permissions
Description
Θ Quick-Snap rotates end effector to the 0° position. 0° is defined as
the position in which the end effector graduation marks are visible to
the operator. This is an absolute command, or in other words, will
automatically rotate to the 0° position, regardless of its current position.
Θ Quick-Snap rotates end effector to the 90° position. The 90° position
is counterclockwise to the 0° position. This is an absolute command,
or in other words, will automatically rotate to the 90° position,
regardless of its current position.
Θ Quick-Snap rotates end effector to the 180° position. The 180°
position is counterclockwise to the 0° position. This is an absolute
command, or in other words, will automatically rotate to the 180°
position, regardless of its current position.
Θ Quick-Snap rotates end effector to the 270° position. The 270°
position is counterclockwise to the 0° position. This is an absolute
command, or in other words, will automatically rotate to the 270°
position, regardless of its current position.