USER MANUAL, RSS-1000-CVSI
7000-5970
Rev.
A
page
289
of
396
6. Tap
to save the template
6.1. Pro Tip: Save the Template with the name of “
Solder Parameter
Template” to aid in
identification of the parameters used and to separate it from normal solder profiles.
7. Once the file name has been entered, tap
to complete the save.
Template Creation Complete!
Pattern
Recognition
Using
Template
1. Install PCBA with designated fixture at the current calibrated height.
2. Verify the Connection Validation Power Supply or RF is in the
OFF
position.
3. Install desired Connection Validation cartridge.
3.1. Verification of cartridge at the correct pivot position can be completed by referring to the
Tip
Alignment
section
3.2. WARNING: Do NOT turn on the Connection Validation Power Supply after installation of
cartridge.
4. Use the jog controls to position the cartridge point over the PCBA.
5. Slowly jog end effector down in the Z-Axis until the cartridge is 5mm above an open area of
PCBA, free of components.
Summary of Contents for RSS-1000-CVSI
Page 21: ...USER MANUAL RSS 1000 CVSI 7000 5970 Rev A page 21 of 396 ROBOT BASE CONNECTIONS N ...
Page 52: ...USER MANUAL RSS 1000 CVSI 7000 5970 Rev A page 52 of 396 2 Tap the Power Button ...
Page 55: ...USER MANUAL RSS 1000 CVSI 7000 5970 Rev A page 55 of 396 2 Tap the Power Button ...
Page 224: ...USER MANUAL RSS 1000 CVSI 7000 5970 Rev A page 224 of 396 5 5 Spiral 1 2 3 8 9 4 7 6 5 ...