FINE
ADJUSTMENT
AFTER
CAMERA
CALIBRATION
Fine adjustment after calibration is used for operators who would like to adjust the position of the
soldering tip relative to the crosshair (such as compensating for a larger pin or pad,) after an invalid
Camera calibration, or after failure of the position verification test.
WARNING: If the height has changed since the last Camera calibration, a full calibration MUST be
performed. This procedure should not be used as a shortcut to calibrate the camera. Doing so may
have undesired results and/or may cause damage to workpiece or unit.
1. Tap the Home Button
to ensure you are at the origin.
2. Tap the Global Settings Button
.
3. Tap the Camera Settings menu.