27.2. A “scaled image” means that any movement commands issued by tapping on the image will
reflect actual distances on the PCBA. For example, if two components were physically 10mm
apart from one another, the displayed image distance may vary, depending on the
magnification (1X, 2X, or 3X). However, in any of the three magnification cases, the operator
would be able to position the end effector over one component, tap on the other component
and the system would travel 10mm.
28. To determine if fine tuning is required, inspect along the edges of the raised surface of the scaling
block displayed in the workspace. The newly scaled image should not have any gap to the left or
above this raised surface (i.e. no bare aluminum should be visible.) Examples have been
provided below.
Gap
Gap
No
Gap
No
Gap