![Metcal RSS-1000-CVSI User Manual Download Page 254](http://html.mh-extra.com/html/metcal/rss-1000-cvsi/rss-1000-cvsi_user-manual_1777464254.webp)
USER MANUAL, RSS-1000-CVSI
7000-5970
Rev.
A
page
254
of
396
14. Once tip is aligned, use the jog controls to position the align the Center Point Tool Assembly to the
circular feature on the calibration fixture.
14.1.
Carefully
jog the end effector down in the Z-Axis in small increments to confirm alignment
has been achieved.
14.1.1. If the alignment tip is out of alignment with the circular feature, use the fine adjustment
jog controls to carefully jog it into place.
Out of Alignment Aligned
Summary of Contents for RSS-1000-CVSI
Page 21: ...USER MANUAL RSS 1000 CVSI 7000 5970 Rev A page 21 of 396 ROBOT BASE CONNECTIONS N ...
Page 52: ...USER MANUAL RSS 1000 CVSI 7000 5970 Rev A page 52 of 396 2 Tap the Power Button ...
Page 55: ...USER MANUAL RSS 1000 CVSI 7000 5970 Rev A page 55 of 396 2 Tap the Power Button ...
Page 224: ...USER MANUAL RSS 1000 CVSI 7000 5970 Rev A page 224 of 396 5 5 Spiral 1 2 3 8 9 4 7 6 5 ...