10. Tap the “Set Fiducial Points” button
10.1. The icon will illuminate blue when active
10.2. Increasing magnification is permitted
10.2.1. See Image Zoom section for magnification instructions.
11. Tap and drag from top left to bottom right of the feature in order to create a box around a location
on the image as the first fiducial point.
11.1. Pro Tip: Select an object or feature that is unique and distinct from any other feature on the
board.
11.1.1. Examples of good objects to select for fiducial points are drilled holes for mounting or
holes drilled specifically for fiducial points of computer vision systems.
11.1.2. Examples of bad objects to select for fiducial points include resistors, capacitors,
sticker labels, and various other components as these can have variations in assembly
from board to board