1. Tap New Profile
to ensure that the workspace is clear of all programmed points.
2. Navigate to Profile Options and tap the waypoint icon
once to toggle to solder point
3. Swipe Up or Down to scroll through the dot parameters until the desired dot parameter that is to
be used is highlighted by the yellow band.
4. Position the end effector at the location of the top left corner of where the array is to be
programmed.
5. Tap the Generate Array button
5.1. The button will illuminate gold to signify the array function is active
6. Tap the Record button
to designate the first point of the array.
7. Tap the Generate Array button once again to signal the end of all patterns that are to be included
within the array
7.1. The button will return to grey in color