POSITION
VERIFICATION
TEST
A successful calibration is crucial to utilization of the software to accurately program using camera
images as well as the other camera-based functions. Therefore, a position verification test is highly
recommended after any calibration to confirm that the calibration was a success. The following steps
will detail how to confirm that a calibration was successful.
1. Using the jog controls, position the crosshair over the circular feature of the Scaling Block
2. Slowly drive end effector down to Scaling Block
2.1. If the calibration was performed successfully, the tip should land at the centroid of the circular
feature, tangent to the circular feature, or somewhere in between, dependent on the offset
calibrated. The location may vary, dependent on angle of manual end effector adjustment,
application location (further from centroid for larger pins of the component to be soldered,
closer to centroid for smaller pins of the component to be soldered,) or an improperly
executed tip alignment.
I
II