9. Tap the record button
10. Jog the end effector in the -X direction in 2.54mm increments for the next three pins, recording a
point at each pin.
10.1. Dependent on the geometry of the component programmed, this may be sufficient for the
program. If this is true to the application skip to step 11. However, Metcal follows the IPC-J-
STD-001 and IPC-A-610 standards when soldering. Therefore, in this example, the
component will be soldered with alternating pins on alternating sides to be compliant.
10.2. Tap
to enter the Edit Profile Screen
10.3. Tap to reach the Edit Segment Screen
10.4. Swipe up/down on the program order until DOT# 7 is highlighted
10.5. Tap
to reorder the point to position 2.
10.6. Swipe up on the Program Order until DOT #4 is highlighted.
10.7. Tap
to reorder point to position 3.