Enterprise Operating System Command Line Interface User Manual 

vi

Contents

New and Changed Commands ......................................................2-2
config ..................................................................................................2-5

config.enterpriseFabMode.setState.........................................2-5
config.features.enterpriseFabMode ........................................2-6
config.features.ficonMS ............................................................2-6
config.features.installKey .........................................................2-7
config.features.NPIV.................................................................2-8
config.features.openSysMS ......................................................2-8
config.features.openTrunking .................................................2-8
config.features.show .................................................................2-9
config.fencing.addPolicy ........................................................2-10
config.fencing.addPort............................................................2-10
config.fencing.deletePolicy ....................................................2-11
config.fencing.removePort .....................................................2-12
config.fencing.setParams........................................................2-12
config.fencing.setState ............................................................2-14
config.fencing.show ................................................................2-14
config.fencing.showTypeTable..............................................2-16
config.ficonCUPZoning.addControlHost ............................2-16
config.ficonCUPZoning.deleteControlHost ........................2-17
config.ficonCUPZoning.setState ...........................................2-17
config.ficonCUPZoning.show ...............................................2-18
config.ficonMS.setMIHPTO ...................................................2-18
config.ficonMS.setState...........................................................2-19
config.ficonMS.show...............................................................2-20
config.ip.ethernet.....................................................................2-20
config.ip.lineSpeed ..................................................................2-21
config.ip.show..........................................................................2-21
config.NPIV.maxPortIDs........................................................2-22
config.NPIV.setState ..............................................................2-23
config.NPIV.show ..................................................................2-23
config.openSysMS.setHostCtrlState .....................................2-24
config.openSysMS.setState.....................................................2-24
config.port.blocked..................................................................2-25
config.port.fan..........................................................................2-25
config.port.name......................................................................2-26
config.port.rxCredits ...............................................................2-26
config.port.show ......................................................................2-27
config.port.showPortAddr.....................................................2-28
config.port.speed .....................................................................2-29
config.port.swapPortByAddr ................................................2-30
config.port.swapPortByNum.................................................2-30
config.port.type........................................................................2-31

Summary of Contents for Enterprise Operating System

Page 1: ...Enterprise Operating System Command Line Interface User Manual P N 620 000134 720 REV A...

Page 2: ...ATA CORPORATION DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTIBILITY AND FITNESS FOR A PARTICULAR PURPOSE In no event shall McDATA Corporation be liable for a incidental indirect special or consequenti...

Page 3: ...System Command Line Interface User Manual iii property of such parties and are reprinted with limited use permission All other trademarks are the property of their respective companies All specificati...

Page 4: ...Enterprise Operating System Command Line Interface User Manual iv...

Page 5: ...meters 1 13 Output 1 14 Logging In and Logging Out 1 14 User Access Rights 1 14 Passwords and Secrets 1 14 login 1 15 logout 1 16 Using the commaDelim Command 1 17 commaDelim 1 17 Handling Command Lin...

Page 6: ...ng show 2 14 config fencing showTypeTable 2 16 config ficonCUPZoning addControlHost 2 16 config ficonCUPZoning deleteControlHost 2 17 config ficonCUPZoning setState 2 17 config ficonCUPZoning show 2 1...

Page 7: ...config security authentication RADIUS deleteServer 2 43 config security authentication RADIUS server 2 43 config security authentication RADIUS show 2 44 config security authentication RADIUS timeout...

Page 8: ...config snmp authTraps 2 69 config snmp deleteCommunity 2 70 config snmp setFaMibVersion 2 70 config snmp setState 2 71 config snmp show 2 71 config switch 2 72 config switch domainRSCN 2 72 config swi...

Page 9: ...stem ipl 2 97 maint system resetConfig 2 97 maint system setOnlineState 2 98 perf 2 99 perf class2 2 99 perf class3 2 100 perf clearStats 2 102 perf errors 2 102 perf link 2 104 perf openTrunking back...

Page 10: ...oldAlerts throughput setParams 2 134 perf thresholdAlerts throughput show 2 135 perf thresholdAlerts throughput showUtilTypeTable 2 135 perf traffic 2 136 show 2 138 show all 2 138 show auditLog 2 139...

Page 11: ...tatus 2 174 show port technology 2 177 show preferredPath showPath 2 178 show security fabricBinding 2 180 show security log 2 181 show security portBinding 2 182 show security switchAcl 2 183 show se...

Page 12: ...Enterprise Operating System Command Line Interface User Manual xii Contents...

Page 13: ...ation Conventions 1 3 1 2 CLI Command Tree 1 5 1 3 CLI Command Tree for the ED 5000 Director 1 21 2 1 Supported Zoning Configurations 2 85 2 2 Throughput Threshold Alerts 2 118 2 3 Alert Counters 2 11...

Page 14: ...xiv Enterprise Operating System Command Line Interface User Manual Tables...

Page 15: ...witch Sphereon 3232 Switch Sphereon 4300 Switch and Sphereon 4500 Switch A limited number of these commands are available on the ED 5000 Director Access through a Telnet client is presumed This public...

Page 16: ...each command in the CLI and the release in which the command was added to the CLI The Glossary defines terms abbreviations and acronyms used in this manual An Index is also provided Manual Updates Che...

Page 17: ...resents important information that is not hazard related ATTENTION An attention notice presents important information about activities that could result in loss of equipment function or loss of data W...

Page 18: ...sed the hardware product from a company other than McDATA should contact that company s service representative for technical support Forwarding Publication Comments We sincerely appreciate any comment...

Page 19: ...es other countries or both Registered Trademarks Trademarks Fabricenter E OS HotCAT Eclipse Intrepid Fibre Channel Director McDATA OPENconnectors OPENready SANvergence SANavigator Sphereon SANpilot SA...

Page 20: ...xx Enterprise Operating System Command Line Interface User Manual Preface...

Page 21: ...ommands Command Line Interface Overview 1 2 Entering Command Line Interface Commands 1 3 Logging In and Logging Out 1 14 Using the commaDelim Command 1 17 Handling Command Line Interface Errors 1 18 U...

Page 22: ...environment using the Ethernet port in the director or switch Although the primary use of the CLI is in host based scripting environments the CLI commands can also be entered directly at a command lin...

Page 23: ...hough the commands cannot be entered with the periods the command line prompts do include the periods Config Port Navigation Conventions Basic command line navigation conventions are supported The fol...

Page 24: ...e end of the line L Control L Redraw the line N Control N Move down one line in the command history P Control P Move up one line in the command history R Control R Redraw the line U Control U Clear th...

Page 25: ...d are documented in this chapter login see login on page 1 15 logout see logout on page 1 16 commaDelim see Using the commaDelim Command on page 1 17 Table 1 2 shows the command tree hierarchy from th...

Page 26: ...openSysMS setState port blocked fan name rxCredits show showPortAddr speed swapPortByAddr swapPortByNum type security authentication interface api outgoing sequence cli sequence eport outgoing sequenc...

Page 27: ...ng addAttachedMembers addMember clearMemList deactivateFabBind deleteMember replacePending showActive showPending portBinding bound show wwn ssh resetKeys setState show switchAcl addRange deleteRange...

Page 28: ...inRSCN edTOV insistDomainId interopMode ltdFabRSCN prefDomainId priority raTOV rerouteDelay speed show zoneFlexPars zoningRSCN system contact date description location name show zoning setDefZoneState...

Page 29: ...Config setOnlineState perf class2 class3 clearStats errors link openTrunking backPressure congestionThresh lowBBCreditThresh setState show unresCongestion preferredPath clearPath setPath setState show...

Page 30: ...centage setParams show showUtilTypeTable traffic show all auditLog epFrameLog config filterClassFFrames noWrap setFilterPort wrap eventLog fabric nodes principal topology fabricLog noWrap wrap feature...

Page 31: ...nds is a typical order in which the zoning commands are entered Note that the order in which commands are entered determines the order in which the show commands display the values Refer to Chapter 2...

Page 32: ...Root maint Maint port Maint Port beacon 4 true Note that you must return all the way to the root of the tree to transition to another extended branch When traversing back to the root the name of each...

Page 33: ...recorded in the history log and the position in the tree does not change as shown in the following example Because the command is not recorded in the history a subsequent asynchronous command navigat...

Page 34: ...elnet client user must log in any time the director or switch is restarted because the current user s access is lost Examples of a restart include an IPL and any power off situation User Access Rights...

Page 35: ...l and the printable ASCII characters login Syntax login Purpose This command allows a Telnet client to connect to the switch Description This command allows the user to log in with either administrato...

Page 36: ...The access rights chosen for the CLI are completely independent of the other product interfaces for example SNMP or McDATA product interfaces Parameters This command has no parameters Command Examples...

Page 37: ...ter This command has one parameter Command Examples Root commaDelim true Config commaDelim 1 Config Port commaDelim false Output Example Output displayed in commaDelim mode is as follows Root show eve...

Page 38: ...ot exist Root confg Error 234 Invalid Command An error associated with fabric or switch issues For example a parameter error is detected by the switch where port 24 is entered for a switch that suppor...

Page 39: ...system contact attribute date Set the system date and time description Set the system description attribute location Set the system location attribute name Set the system name attribute show Display...

Page 40: ...R config port CR The pound sign cannot be used after any other characters a command for example to start a comment The following is an invalid script line Root maint system beacon true Turn on beaconi...

Page 41: ...vailable commands login logout and commaDelim are described previously in this chapter The following config maint and show commands are described in Chapter 2 CLI Commands Table 1 3 CLI Command Tree f...

Page 42: ...is enabled by default Any changes to the enabled state of the Telnet server are retained through system restarts and power cycles Ethernet Connection Loss If the Ethernet cable is disconnected from th...

Page 43: ...e configuration data from all switch and director products running E OS versions 4 0 and higher The CBR utility is available for no charge in the Technical Documents section of the McDATA website at w...

Page 44: ...1 1 24 Enterprise Operating System Command Line Interface User Manual Backup and Restoration...

Page 45: ...bes the Command Line Interface CLI commands including their syntax purpose and parameters as well as examples of their usage and any output that they generate Command Overview 2 2 New and Changed Comm...

Page 46: ...r this edition of the Enterprise Operating System Command Line Interface User Manual config fencing addPolicy on page 2 10 config fencing addPort on page 2 10 config fencing deletePolicy on page 2 11...

Page 47: ...page 2 36 config security authentication interface osms setKey on page 2 38 config security authentication interface osms outgoing on page 2 37 config security authentication interface serial enhanced...

Page 48: ...ow on page 2 64 config security ssh resetKeys on page 2 61 config security ssh setState on page 2 61 config security ssh show on page 2 61 config switch zoneFlexPars on page 2 80 perf thresholdAlerts...

Page 49: ...ands except for the config zoning commands use the USASCII character set All of the characters in this 128 character set the first 7 bit subset of the ISO 8859 1 Latin 1 character set are valid Any ex...

Page 50: ...Root config features enterpriseFabMode 1 NOTE The command config enterpriseFabMode setState on page 2 5 has functionality that is identical to this command config features ficonMS Syntax ficonMS ficon...

Page 51: ...nline when this command is executed NOTE If any currently installed features are being removed by the new feature key the switch must be offline when the command is given Parameters This command has o...

Page 52: ...d state of the Open Systems Management Server OSMS OSMS is a feature that allows host control and inband management of the director or switch through a management application that resides on an open s...

Page 53: ...switch Parameters This command has no parameters Command Example Root config features show Output The product feature data is displayed as a table that includes the following properties openTrunkingS...

Page 54: ...ax addPolicy name Purpose This command configures a new fencing policy and assigns it a name The new policy is assigned default settings which must be changed before the policy is activated See config...

Page 55: ...ntain both port types and individual ports Command Example Root config fencing addPort 24 Root config fencing addPort eport config fencing deletePolicy Syntax deletePolicy name Purpose This command de...

Page 56: ...Syntax setParams name typeNumber limit period Purpose This command sets the type limit and period values for a specified fencing policy name The name of the fencing policy You can also enter all for...

Page 57: ...automatically disabled Acceptable values are in the range of 1 255 You may also enter default for this argument which will set the default limit value for this fencing policy type period The number of...

Page 58: ...nabled state of the specified fencing policy A policy cannot be activated if it contains ports that are already controlled by a different fencing policy of the same type Parameters This command has tw...

Page 59: ...the name parameter then the output shows the following information Output Example The output from the config fencing show command displays as follows Name Type State Default Protocol Error Policy Pro...

Page 60: ...d has no parameters Command Example Root config fencing showTypeTable Output Example The output from the config fencing showTypeTable command displays as follows Number Fencing Policy Types 1 Protocol...

Page 61: ...e enabled state of FICON CUP Zoning The FICON Management Server feature key must be installed in order to enable the FICON CUP Zoning State The Sphereon 4300 and Sphereon 4500 switches do not accept t...

Page 62: ...ing information Output Example The output from the config ficonCUPZoning show command displays as follows FICON CUP Zoning State Enabled Host Control List 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F...

Page 63: ...is displayed on a Sphereon 3016 only if the feature key is installed NOTE If the FICON Management Server is enabled the default management style is the FICON Management Style The Open Systems Managem...

Page 64: ...om the config ficonMS show command displays as follows Ficon MS State Disabled Ficon MIHPTO seconds 180 config ip ethernet Syntax ethernet ipAddress gatewayAddress subnetMask Purpose This command sets...

Page 65: ...s This command has no parameters Command Example Root config ip show ipAddress Specifies the new IP address for the director or switch The address must be entered in dotted decimal format for example...

Page 66: ...lowed on the specified port Parameters This command has two parameters Command Example Root config NPIV maxPortIDs 128 Root config NPIV portNumber 60 IP Address The IP address Gateway Address The gate...

Page 67: ...s Parameters This command has no parameters Command Example Root config NPIV show Output This command displays the following NPIV configuration data Output Example The output from the config NPIV show...

Page 68: ...SysMS setState Syntax setState osmsState Purpose This command sets the enabled state of the Open Systems Management Server OSMS OSMS is a feature that allows host control and inband management of the...

Page 69: ...mmand sets the fabric address notification FAN state for a port Sphereon 4300 and Sphereon 4500 switches only This configuration can be applied to any port regardless of its current configuration The...

Page 70: ...he number of initial BB Credits for a given port The number of credits assigned must fall between the minimum and maximum allowed values for the port portNumber Specifies the port number Valid values...

Page 71: ...32 143 for the Intrepid 6140 numBBCredits Specifies the number of Rx BB Credits to assign the specified port For the Sphereon 4300 and Sphereon 4500 the RxCredits per port must be between 2 and 12 The...

Page 72: ...t address configuration for all ports NOTE The command show port showPortAddr on page 2 173 has functionality that is the same as this command Port Number The port number Name The configured port name...

Page 73: ...igured to operate at 1 Gb sec 2 Gb sec or a negotiated speed The port speed can be set only to 1 Gb sec if the switch speed is 1 Gb sec An attempt to set the port speed to 2 Gb sec or to negotiate in...

Page 74: ...his operation Parameters This command has two required parameters Command Example Root config port swapPortByAddr 1e 1f config port swapPortByNum Syntax swapPortByNum portNum1 portNum2 portNumber Spec...

Page 75: ...e feature is enabled For more information see the McDATA Sphereon 4300 Switch Installation and Service Manual 620 000171 The port configurations function as follows F_Port cannot be used as an intersw...

Page 76: ...adding or deleting fabric members The edited copy can then be activated to the fabric It should be noted that not all verification of membership lists can be made in the pending copy Therefore it is...

Page 77: ...s command sets the sequence that the API interface will use to authenticate When the preferred method cannot be contacted the backup method will be used to authenticate the API session Parameters This...

Page 78: ...d one optional parameter NOTE A preferred method of local and a backup method of RADIUS is not an accepted combination because the local method can always be contacted Command Example Root config secu...

Page 79: ...od will be used to authenticate the remote end of the ISL NOTE This command requires that the SANtegrity Authentication feature key be installed Parameters This command has one required parameter and...

Page 80: ...This command requires that the SANtegrity Authentication feature key be installed Parameters This command has one parameter Command Example Root config security authentication interface eport outgoing...

Page 81: ...must be configured prior to setting the outgoing state to enabled NOTE The SANtegrity Authentication feature key must be installed to configure the OSMS outgoing state Parameters This command has one...

Page 82: ...urned to the initial prompt that the command was executed from No characters will be echoed back to the screen when entering a password or when confirming a password NOTE The SANtegrity Authentication...

Page 83: ...eter Command Example Root config security authentication interface show Web Output Example The output for the config security authentication interface show command displays as follows Interface Web Ou...

Page 84: ...ts the outgoing override state for a single port This setting allows you to override the default outgoing authentication state for either the E_port or N_port interface The default setting will cause...

Page 85: ...ser names in the local database for the specified interface Output Example The output for the config security authentication port show command displays as follows portNumber Specifies the port number...

Page 86: ...mmand Example Root config security authentication RADIUS attempts 3 20 config security authentication RADIUS deadtime Syntax deadtime minutes Purpose This command configures the number of minutes a RA...

Page 87: ...rver index IP port Purpose This command adds or modifies one RADIUS server at a given index that will be used for authentication Servers are queried in the order listed so the primary server must be t...

Page 88: ...oot config security authentication RADIUS show Output This command displays all three configured RADIUS servers Output Example The output for the config security authentication RADIUS show command dis...

Page 89: ...switch secret is used for all incoming CHAP challenges on the E port and N port interfaces After issuing this command you are directed to a password prompt where the actual 16 byte secret is entered A...

Page 90: ...ig security authentication user add Syntax add username interface1 interface2 Purpose This command adds a new user to the local authentication database Each user can be assigned a combination of inter...

Page 91: ...sername E Port and N Port usernames must be entered as a standard colon delimited WWN All characters in the printable USASCII character set are valid with the exception of spaces single quotes and dou...

Page 92: ...ation database The user password and the combination of interfaces can be modified with this command After executing this command you are prompted to enter a password similar to behavior of the user a...

Page 93: ...or will be shown This parameter can be from 1 23 characters in length for an API Web or CLI username E Port and N Port usernames must be entered as a standard colon delimited WWN All characters in the...

Page 94: ...rator config security authentication user show Syntax show interface Purpose This command displays a single interface from the local authentication database Parameters This command has one optional pa...

Page 95: ...t CLI commands which are single action commands that take effect immediately Most of the Fabric Binding commands affect a temporary copy of an FBML in the work area which is called the Pending FBML Wh...

Page 96: ...and directors are unattached if they have been added manually to the pending FBML or if they segmented from the local fabric Enable Disable and Online State Functions In order for Fabric Binding to fu...

Page 97: ...tely The CLI verifies the list before activating it to the fabric Parameters This command has no parameters Command Example Root config security fabricBinding activatePending config security fabricbin...

Page 98: ...learMemList Syntax clearMemList Purpose This command clears the Pending FBML in the working area Members that are attached remain in the list because the Pending FBML must contain all attached members...

Page 99: ...a member from the Pending FBML in the fabric binding work area The local member and attached members cannot be deleted from the list NOTE Changes are not activated to the fabric until the activatePen...

Page 100: ...show security fabricBinding on page 2 180 Parameters This command has no parameters Output This command displays the following fabric binding configuration data Output Example The output from the con...

Page 101: ...11 22 33 44 55 66 77 Unattached Domain 2 88 99 AA BB CC DD EE FF Attached Domain 14 11 55 35 45 24 78 98 FA Attached config security portBinding The Port Binding CLI commands enable you to bind a spe...

Page 102: ...lid port number values are 0 11 for the Sphereon 4300 0 15 for the Sphereon 3016 and 3216 0 23 for the Sphereon 4500 0 31 for the Sphereon 3032 and 3232 0 63 for the Intrepid 6064 0 127 and 132 143 fo...

Page 103: ...er boundWwn Purpose This command configures the single device WWN to which a port is bound portNumber Specifies the port number for which the port binding configuration will be shown Valid values are...

Page 104: ...ndWwn is configured and the portBindState is Active only the device described by boundWwn is able to connect to the specified port Inactive the WWN is retained but any device can connect to the specif...

Page 105: ...s Command Example Root config security ssh resetKeys config security ssh setState Syntax setState sshEnableState Purpose This command sets the enabled state for the SSH interface In order for an SSH c...

Page 106: ...tion to the product config security switchAcl addRange Syntax addRange startIPAddress endIPAddress Purpose This command adds a new range of IP addresses to the access control list Parameters This comm...

Page 107: ...2 config security switchAcl setState Syntax setState aclEnabledState Purpose This command sets the enabled state of the access control list In order for the access control list to be enforced the stat...

Page 108: ...11 15 1 200 11 255 128 config security switchBinding Switch Binding CLI commands allow you to enable the product to communicate only with nodes switches and directors that are listed on the Switch Bin...

Page 109: ...e is disabled you can disable Switch Binding If Enterprise Fabric Mode is enabled and the director or switch is online you cannot disable Switch Binding If Enterprise Fabric Mode is enabled and the di...

Page 110: ...ty switchBinding deleteMember AA 99 23 23 08 14 88 C1 config security switchBinding setState Syntax setState switchBindingState Purpose This command sets the switch binding state on the switch wwn Spe...

Page 111: ...switch without restrictions eRestrict Enable switch binding and restrict E_Port connections E_Ports are prevented from forming ISL connections unless explicitly identified in the SBML F_Port connecti...

Page 112: ...3 44 55 66 77 88 99 AA BB CC DD EE FF 11 55 35 45 24 78 98 FA config snmp addCommunity Syntax addCommunity commIndex commName writeAuthorization trapRecipient udpPortNum Purpose This command adds an S...

Page 113: ...Specifies the community name of the community specified by commIndex The community name must not exceed 32 characters in length Valid characters include all those in the ISO Latin 1 character set Dupl...

Page 114: ...ts the version of the Fibre Alliance MIB with which the SNMP agent interacts The version number can be set to 3 0 or 3 1 Parameters This command has one parameter Command Example Root config snmp setF...

Page 115: ...ch configuration data is displayed as a table that includes the following properties enabledState Sets the state of the SNMP agent This parameter can be set to enable or disable Boolean 1 and 0 values...

Page 116: ...the product Some of the config switch commands require that the switch be set offline Use the maint system setOnlineState to set the switch offline If these commands are entered while the switch is o...

Page 117: ...before this command is entered Special care should be used when scripting this command due to its relationship with R_A_TOV Parameters This command has one parameter Command Example Root config switch...

Page 118: ...entered Parameters This command has one parameter Command Example Root config switch interopMode open config switch ltdFabRSCN Syntax ltdFabRSCN ltdFabRSCNState insistentDomainIdState Specifies wheth...

Page 119: ...offline to complete this command NOTE The switch must be set offline before this command is entered Parameters This command has one parameter Command Example Root config switch prefDomainId 1 config s...

Page 120: ...al sets the numerical switch priority to 1 The switch with a priority of 1 becomes the principal switch however if two or more switches have a priority of 1 the switch with the lowest WWN becomes the...

Page 121: ...op count is less than a previous path with a minimum hop count This may result in frames being delivered to a destination out of order because frames sent over the new shorter path may arrive ahead of...

Page 122: ...operate at 1 Gbps or 2 Gbps If the switch has FPM cards configuring the switch speed to 2 Gbps makes all the ports on the FPM cards inactive and their operational state will be set to inactive FPM por...

Page 123: ...me Out Value This value is set in tenths of a second E_D_TOV Error Detect Time Out Value This value is set in tenths of a second Preferred Domain Id The preferred domain ID of the switch Switch Priori...

Page 124: ...d Fabric RSCN Disabled Zone FlexPars Fabric config switch zoneFlexPars Syntax zoneFlexPars zoneFlexParstate Purpose This command configures the state of Zone Flex Pars Zoning RSCN When enabled allows...

Page 125: ...offline or online when this command is executed Parameters This command has one parameter Command Example Root config switch zoningRSCN 1 config system contact Syntax contact systemContact Purpose Th...

Page 126: ...oot config system date 10 09 2001 14 07 55 config system description Syntax description systemDescription Purpose This command sets the system description string systemContact Specifies the new system...

Page 127: ...system name Syntax name systemName Purpose This command sets the system name attribute Parameters This command has one required parameter Command Example Root config system name Joe s Switch config s...

Page 128: ...a different way from most CLI commands which are single action commands that take effect immediately A zoning configuration is typically too complicated to be described by a single command so the fir...

Page 129: ...Zoning Library values in this table have been tested and are supported For the latest limits refer to the Supported Fabrics Configuration Document located on www mcdata com in the Resource Library or...

Page 130: ...rector is set to Open Fabric 1 0 mode NOTE A product can have at most 1024 zone members in its zones NOTE The ED 5000 supports a maximum of 512 zones Parameters This command has the following paramete...

Page 131: ...g zoning addZone Syntax addZone zoneName Purpose This command adds a new empty zone to the zone set in the work area NOTE Changes are not activated on the switch until the config zoning activateZoneSe...

Page 132: ...clearZone TheNotUltimateAtAllZone config zoning clearZoneSet Syntax clearZoneSet Purpose This command clears the zone set contained in the work area removing all zones and takes effect immediately Th...

Page 133: ...Number Purpose This command deletes a domain ID and port number for a zone member in the specified zone in the work area Parameters This command has three parameters Command Example Root config zoning...

Page 134: ...e zoneName Purpose This command deletes a zone from the zone set in the work area NOTE Changes are not activated on the switch until the config zoning activeZoneSet command is issued Parameters This c...

Page 135: ...config zoning activateZoneSet command is issued Parameters This command has one parameter oldZoneName Specifies the current zone name of the zone to be renamed newZoneName Specifies the new zone name...

Page 136: ...faultZoneState Purpose This command enables or disables the default zone and takes effect immediately fabric wide NOTE This command takes effect immediately in the fabric Parameters This command has o...

Page 137: ...9B AB ZoneMember 10 00 00 00 C9 22 9B C6 ZoneMember 10 00 00 00 C9 22 9B AB Zone TheNotUltimateAtAllZone ZoneMember Domain 2 Port 63 config zoning showPending Syntax showPending Purpose This command s...

Page 138: ...ed False ZoneSet TheNewUltimateZoneSet Zone TheNewUltimateZone ZoneMember Domain 10 Port 6 ZoneMember Domain 15 Port 2 Zone TheNewNotSoUltimateZone ZoneMember 10 00 00 00 C9 22 9B AB ZoneMember 10 00...

Page 139: ...s restored maint port beacon Syntax beacon portNumber beaconState Purpose This command enables or disables port beaconing for a port Parameters This command has two required parameters Command Example...

Page 140: ...coning for the specified port Parameters This command has one parameter Command Example Root maint port reset 4 maint system beacon Syntax beacon beaconState Purpose This command enables or disables u...

Page 141: ...ig Purpose This command resets all NV RAM configuration parameters to their default values including feature keys and IP addresses NOTE This command IPLs the switch Connection from the CLI to the swit...

Page 142: ...Syntax setOnlineState onlineState Purpose This command sets the switch online or offline Parameters This command has one parameter Command Examples Root maint system setOnlineState true Root maint sy...

Page 143: ...lue of the counter is 4 294 967 296 x 12 1842953 51 541 450 505 perf class2 Syntax class2 portNumber Purpose This command displays port Class 2 counters for a single port Parameters This command has o...

Page 144: ...nnel Class 2 frames that the port has transmitted RxWords The number of Class 2 4 byte words within frames that the port has received TxWords The number of Class 2 4 byte words within frames that the...

Page 145: ...nd 3232 0 63 for the Intrepid 6064 0 127 and 132 143 for the Intrepid 6140 Port The port number RxFrames The number of Fibre Channel Class 3 frames that the port has received TxFrames The number of Fi...

Page 146: ...rt statistics for an individual port or for all ports Parameters This command has one parameter Command Example Root perf clearStats 4 Root perf clearStats all perf errors Syntax errors portNumber Pur...

Page 147: ...y the port hardware Disc Frms The number of received frames discarded due to a frame size of less than size words or to frames dropped because the BB_Credit was zero This number is counted during the...

Page 148: ...one parameter Command Example Root perf link 2 Output The port link counter data is displayed as a table that includes the following statistics portNumber Specifies the port number Valid values are 0...

Page 149: ...ts initiated by this director or switch LIPS In The number of Loop Initialization Primitives LIPS detected on this switch loop port LIPS Out The number of LIPS generated on this switch loop port Link...

Page 150: ...BB_credit threshold is defined backPressureState This parameter can be set to enable or disable OpenTrunking back pressure Boolean 1 and 0 values may also be substituted If the state is configured to...

Page 151: ...nk that lacks BB_Credits even if the loading threshold is significantly below the limit Parameters This command has one parameter Command Example Root perf openTrunking lowBBCreditThresh 20 perf openT...

Page 152: ...e Sphereon 4300 0 15 for the Sphereon 3016 and 3216 0 23 for the Sphereon 4500 0 31 for the Sphereon 3032 and 3232 0 63 for the Intrepid 6064 0 127 and 132 143 for the Intrepid 6140 Congestion Thresho...

Page 153: ...is made to the Event Log and an SNMP trap is generated if SNMP is configured Parameters This command has one parameter Command Example Root perf openTrunking unresCongestion 1 Backpressure The curren...

Page 154: ...th consists of the source port of the switch or director being configured the exit port of that switch or director and the domain ID of the destination switch or director Each switch or director must...

Page 155: ...tination domain ID and source port NOTE You cannot set a path where the Destination Domain ID is the same as the Switch s Domain ID destDomainId Specifies the destination domain ID Valid domain IDs ar...

Page 156: ...n ID Valid domain IDs are in the range 1 31 sourcePort Specifies the number of the source port Valid port numbers values are 0 11 for the Sphereon 4300 0 15 for the Sphereon 3016 and 3216 0 23 for the...

Page 157: ...parameter results in output that shows all configured and actual exit ports for the other parameter If the destination domain is set to all then all paths from the specified source port are displayed...

Page 158: ...Sphereon 4500 0 31 for the Sphereon 3032 and 3232 0 31 for the ED 5000 0 63 for the Intrepid 6064 0 127 and 132 143 for the Intrepid 6140 Or you can specify all to show all paths to the destination d...

Page 159: ...ath all 15 Preferred Path State Enabled Destination Domain Preferred Exit Port 1 23 3 24 4 23 17 12 sourcePort set to all Root perf preferredPath showPath 1 all Preferred Path State Enabled Source Por...

Page 160: ...118 NOTE The perf thresholdAlerts commands are standard command line interface features They do not require a feature key Creating Threshold Alerts The tasks you need to complete to create and activa...

Page 161: ...less it is in the disabled state Activating a Throughput Threshold Alert In order to activate a throughput threshold alert using the CLI you must enter certain commands in order Enable the threshold a...

Page 162: ...thresholdAlerts throughput showUtilTypeTable on page 2 135 6 Once the alert is fully configured it can be activated using the perf thresholdAlerts setState command described on 2 127 An alert cannot b...

Page 163: ...Class2BusiedFrames 16 Class2RejectedFrames 17 Class3DiscardedFrames 18 Physical Link Errors Set see below 19 Link Sequence Counts Set see below 20 Logical Link Errors Set see below 21 LIPS Detected S...

Page 164: ...ds CRC Errors Frames Too Short Delimiter Errors Link Sequence Counts Summed Set Link Resets Received Link Reset Sent OLS Received OLS Sent Logical Link Errors Summed Set Discarded Frames Address ID Er...

Page 165: ...the commaDelim Command on page 1 17 Command Example Root perf thresholdAlerts counter addAlert checklinks perf thresholdAlerts counter addPort Syntax addPort name portNumber Purpose This command adds...

Page 166: ...thresholdAlerts counter addPort checklinks 12 perf thresholdAlerts counter removePort Syntax removePort name portNumber Purpose This command removes a port from the specified counter threshold alert...

Page 167: ...ssociate a counter with the threshold alert name created using the perf thresholdAlerts counter addAlert command NOTE An alert cannot be modified unless it is in the disabled state Verify that the ale...

Page 168: ...parameters Example The meaning for each of these inputs can best be described using the following example sentence name The name of a counter threshold alert as defined by the command perf thresholdA...

Page 169: ...has one parameter NOTE The output of this command truncates threshold alert names that are longer than 51 characters If you specify lengthy names you can display the complete name by entering the com...

Page 170: ...ot perf threshAlerts counter showStatisticTable Output Example The output from the perf thresholdAlerts counter showStatisticTable command displays as follows Number Counter or Counter Set 1 Link Rese...

Page 171: ...f the specified threshold alert Parameters This command has the following parameters Command Example Root perf thresholdAlerts setState checklinks enabled perf thresholdAlerts show Syntax show name Th...

Page 172: ...pe of the alert abbreviated to 17 chars Tx Util TTA Transmit Utilization Rx Util TTA Receive Utilization Tx Rx Util TTA Transmit or Receive Utilization Link Resets Sent CTA Link Resets Sent Link Reset...

Page 173: ...the other throughput threshold alert commands The default settings for a new counter threshold alert are as follows Address ID Errors CTA Address ID Errors Cls2 BusiedFrms CTA Class 2 Busied Frames Cl...

Page 174: ...ted mode using the commaDelim command For more information see Using the commaDelim Command on page 1 17 Command Example Root perf thresholdAlerts throughput addAlert port6Rx perf thresholdAlerts thro...

Page 175: ...ntax removePort name portNumber Purpose This command removes a port from the specified throughput threshold alert name The name of a throughput threshold alert as defined by the command perf threshold...

Page 176: ...ghput statistic that is used to trigger the throughput threshold alert NOTE An alert cannot be modified unless it is in the disabled state Verify that the alert is disabled before executing this comma...

Page 177: ...and has the following parameters Command Example Root perf thresholdAlerts throughput setUtilPercentage eportRx 70 name The name of a throughput threshold alert as defined by the command perf threshol...

Page 178: ...xample Root perf thresholdAlerts throughput SetParams eportRx 1 10 name The name of a throughput threshold alert as defined by the command perf thresholdAlerts throughput addAlert described on 2 129 d...

Page 179: ...rf thresholdAlerts throughput show eportRx Output Example The output from the perf thresholdAlerts throughput show command displays as follows Name 90 Receive Throughput Threshold Ports 5 8 12 20 24 U...

Page 180: ...port Parameters This command has one parameter Command Example Root perf traffic 2 Output The port traffic counter data is displayed as a table that includes the following statistics along with a wra...

Page 181: ...ames 23 2953184 TxFrames 12 1842953 RxWords 65 2953184 TxWords 32 1842953 TxFrames The number of Fibre Channel Class 2 and Class 3 frames that the port has transmitted RxWords The number of 4 byte wor...

Page 182: ...erator show all Syntax all Purpose This command displays all configuration and status information available The command results in a sequential display of the output of other CLI show commands This se...

Page 183: ...isplays the entries of the audit log after the last time the log was cleared Parameters This command has one optional parameter Command Example show auditLog Output The output from this command displa...

Page 184: ...ters This command has no parameters Command Example Root show epFrameLog config Output The output from this command displays the following data Output Example Filter Class F Frames Disabled Filter Por...

Page 185: ...ommand has one optional parameter If no parameters are entered it will show the current state Command Example Root show epFrameLog setFrameLogPort 63 enable Specifies the on off state Valid values are...

Page 186: ...are NOTE This log will not wrap The log will stop collecting entries after is it filled Parameters This command has one optional parameter If no parameter is specified then the 500 entries of the log...

Page 187: ...151617 18191A1B 1C1D1E1F show epFrameLog wrap Syntax wrap clear Purpose This command allows the user to view the contents of the wrapping region of the FC2 frame log The log entries will not persist I...

Page 188: ...0B 0C0D0E0F 10111213 14151617 18191A1B 1C1D1E1F 37 11 24 03 11 30A 38 O i3 n 2112 Header 22000025 000000EF E1000000 00000000 FFFF0000 00000000 PL 00010203 04050607 08090A0B 0C0D0E0F 10111213 14151617...

Page 189: ...the non wrapping region of the fabric log The log entries will not persist IMLs or power cycles it will not be stored in NV RAM NOTE This log will not wrap The log will stop collecting entries after i...

Page 190: ...8 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94...

Page 191: ...301 Port Offline Online 26437 Ports 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57...

Page 192: ...34 7C CC 57 86 37 23 2 98 45 75 25 7B 35 30 34 2 27 35 3E 69 63 34 22 11 2 29 81 24 74 57 32 48 98 6 25 F2 35 7A 25 22 11 0B 18 F1 23 96 43 56 A3 AA 12 18 45 4D 2B 22 62 9B 19 91 show fabric principa...

Page 193: ...ote WWN RemDID RemPrt 02 30 40 32 34 34 32 21 2 24 24 45 73 49 05 43 22 11 10 2 25 24 45 73 49 05 43 22 11 10 3 26 24 45 73 49 05 43 22 11 10 4 24 45 73 49 05 43 22 11 10 2 02 30 40 32 34 34 32 21 2 2...

Page 194: ...s Management Server OSMS Enabled Flex Ports 8 Flex Ports Enabled SANtegrity Fabric Binding Active SANtegrity Switch Binding Enabled SANtegrity Enterprise Fabrics Active Open Trunking Open Trunking Ena...

Page 195: ...Protocol Errors Enabled Protocol Errors 2 Protocol Errors Disabled Safety 2 Protocol Errors Enabled Root show fencing Protocol Errors 2 Name Protocol Errors 2 Ports 2 4 7 20 24 Type Protocol Errors L...

Page 196: ...onCUPzoning Output The data is presented as a table with the following properties Output Example FICON CUP Zoning State Enabled Host Control List 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 00 show f...

Page 197: ...on MIHPTO value in seconds FRU The FRU name This may show Unknown or Not Installed if the FRU is not installed Position The relative position of the FRU that is its slot State The state of the FRU Val...

Page 198: ...0399 700 223456789 Off 831 show ip ethernet Syntax ethernet Purpose This command displays ethernet attributes Parameters This command has no parameters Command Example Root show ip ethernet Output The...

Page 199: ...isplays as follows Date Time Port Link Incident Event 02 27 03 01 28P 20 Not Operational primitive sequence NOS received 02 27 03 01 28P 4 Primitive sequence timeout 02 27 03 01 27P 62 Not Operational...

Page 200: ...44 55 00 80 20 11 22 33 44 55 66 80 8 10 2 00 11 22 33 44 55 00 81 20 11 22 33 44 55 66 81 10 10 2 3 00 11 22 33 44 55 00 82 20 11 22 33 44 55 66 82 11 10 2 3 00 11 22 33 44 55 00 83 20 11 22 33 44 55...

Page 201: ...ameServer Output The device information data is displayed as a table that includes the following properties Type The type N NL F NL F FL E B Port Id The 24 bit Fibre Channel address Port Name The port...

Page 202: ...N 011300 00 11 22 33 44 55 66 88 10 11 22 33 44 55 66 88 2 3 2 FC4 Types 0 ISO IEC 8802 2 LLC 1 ISO IEC 8802 2 LLC SNAP 2 SCSI FCP 3 SCSI GPP 4 IPI 3 Master 5 IPI 3 Slave 6 IPI 3 Peer 7 CP IPI 3 Maste...

Page 203: ...2 FL 000001 00 11 22 33 44 55 66 03 20 11 22 33 44 55 66 77 2 0 Loop Node 1 Loop Port 7 FL 000002 00 11 22 33 44 55 66 04 20 11 22 33 44 55 66 77 3 2 Loop Node 2 Loop Port 7 show NPIV config Syntax c...

Page 204: ...Example NPIV state Enabled Port Max Allowed NPIV Logins 1 10 2 10 3 10 4 0 5 0 7 130 show openSysMS config Syntax config Purpose This command displays the Open System Management Server state and the...

Page 205: ...Open System Management Server Host Control state Unresolved Congestion The current enabled disabled state of the unresolved congestion trunking feature Backpressure The current enabled disabled state...

Page 206: ...yntax reroutelog clear Purpose This command displays Open Trunking Re route Log information ATTENTION If the switch is restarted as occurs during IPL IML configuration reset feature key installation o...

Page 207: ...mple Root show port config Output The port configuration attributes are displayed as a table that includes the following properties Date Time The date time when the rerouting event occurred Rcv The po...

Page 208: ...iguration Use all for one of the command s parameters to display all configured and actual exit ports for either the destination domain ID or the specified source Port You cannot specify all for both...

Page 209: ...64 0 127 and 132 143 for the Intrepid 6140 Or you can specify all to show all exit ports to the destination domain ID specified for the destDomainId parameter Destination Domain The destination domain...

Page 210: ...meters Root show port exit 21 10 Exit Port 45 Output with destDomainId set to all Root show port exit all 15 Destination Domain Exit Port 1 23 2 No Domain 3 23 31 No Domain Output with sourcePort set...

Page 211: ...44 2 Gb sec 2 Gb sec 8 10 00 80 08 11 22 33 44 2 Gb sec 2 Gb sec 9 10 00 80 09 11 22 33 44 2 Gb sec 2 Gb sec 10 10 00 80 10 11 22 33 44 1 Gb sec 2 Gb sec 11 10 00 80 11 11 22 33 44 1 Gb sec 2 Gb sec 1...

Page 212: ...or the Intrepid 6140 FC Addr The Fibre Channel address of nodes attached to this port Private devices are assigned address strings of 0000 followed by the two digit hexadecimal Arbitrated Loop Physica...

Page 213: ...55 00 77 20 11 22 33 44 55 66 77 6129AE 10 3 00 11 22 33 44 55 00 77 20 11 22 33 44 55 66 77 6129FD 10 2 3 00 11 22 33 44 55 00 77 20 11 22 33 44 55 66 77 6129FE 10 2 3 00 11 22 33 44 55 00 77 20 11 2...

Page 214: ...4 602 100 289 300 1 779 4 998 show port opticInfo Syntax OpticInfo Purpose This command displays information about the optic Parameters This command has no parameters Command Example show port opticIn...

Page 215: ...w portNumber Purpose This command displays the port configuration for a single port Parameters This command has one parameter Command Example Root show port profile portNumber 138 Output The port prof...

Page 216: ...onfigured port speed Beaconing Beaconing state FAN FAN state FC Address The Port Fibre Channel address Attached WWN The node WWN of the device at the remote end of the link A loop port will display th...

Page 217: ...ddress configuration for all ports NOTE The config port showPortAddr on page 2 28 has functionality that is identical to this command Parameters This command has no parameters Command Example Root sho...

Page 218: ...for example Segmented E_Port Invalid Attachment Not Installed Online Offline Not Operational No Light Testing Port Failure Link Reset or Inactive Type The operational port type If the configured port...

Page 219: ...gurations 05 Build Fabric Protocol Error 06 No Principal Switch 07 No Response from Attached Switch 08 ELP Retransmission Failure Timeout If the operational state is Invalid Attachment only the follow...

Page 220: ...63 Off 7 Segmented E_Port ePort 10 00 80 00 11 22 33 47 Off 02 8 Online ePort 10 00 80 00 11 22 33 88 Off 9 Offline fPort 10 00 80 00 11 22 33 49 Off 10 Inactive ePort 10 00 80 00 11 22 33 50 Off 26 1...

Page 221: ...M 50um 2 LC Long LC Long M M 50um 3 MT_RJ Long LC Long M M 50um 4 MT_RJ Long LC Long M M 50um 5 MT_RJ Long LC Long M M 50um 6 LC Long LC Long M M 50um 7 LC Long LC Long M M 50um 8 LC Long LC Long M M...

Page 222: ...domain is set to all all paths from the specified source port are displayed If the source port is set to all the output shows all source port paths to the specified domain Parameters This command has...

Page 223: ...Path State Enabled Destination Domain Preferred Exit Port Actual Exit Port 1 23 23 3 24 No Path 4 23 23 17 12 No Source Destination Domain The destination domain ID to which a preferred path has been...

Page 224: ...ity fabricBinding Output The fabric binding configuration data is displayed as a table that includes the following properties Output Example The output from the show security fabricBinding command dis...

Page 225: ...ational Successful Connection 375 Desc EWS User Connected clear This optional parameter causes all security log entries to be cleared Reason The reason code for the security event Date Time The date a...

Page 226: ...uthentication Not Provided Data Port 0100 WWN 01 02 03 04 05 06 07 08 show security portBinding Syntax portBinding Purpose This command shows the port binding configuration for all ports Parameters Th...

Page 227: ...00 14 Inactive 00 00 00 00 00 00 00 00 15 Inactive 00 00 00 00 00 00 00 00 show security switchAcl Syntax switchAcl Purpose This command displays the contents of the Switch Access Control List Parame...

Page 228: ...yed as a table that includes the following properties Output Example The output from the show security switchBinding command displays as follows Switch Binding State Enabled and Restricting E Ports 00...

Page 229: ...not respond to any requests and does not produce any traps FA MIB Version Number Version of the MIB that the SNMP agent is configured to use Authentication Traps The state of the authentication traps...

Page 230: ...Parameters This command has no parameters Command Example Root show switch Output The switch attributes data is displayed as a table that includes the following properties State The state of the switc...

Page 231: ...g switch interopMode on page 2 74 Active Domain Id The active domain ID of the switch This ID may or may not be the same as the preferred domain ID World Wide Name The WWN for the switch Insistent Dom...

Page 232: ...imited Fabric RSCN Disabled show system Syntax system Purpose This command displays a set of system attributes Parameters This command has no parameters Command Example Root show system Output The sys...

Page 233: ...command For more information see config system location on page 2 83 Serial Number The serial number for the system Type Number The type number for the system Model Name The model name for the system...

Page 234: ...ld alert truncated to 45 characters Type The trigger statistic or threshold type of the alert abbreviated to 17 characters These include Tx Util TTA Transmit Utilization Rx Util TTA Receive Utilizatio...

Page 235: ...ess ID Errors Cls2 BusiedFrms CTA Class 2 Busied Frames Cls2 RejectedFrms CTA Class 2 Rejected Frames Cls3 DiscardFrms CTA Class 3 Discarded Frames Phys Lnk Err Set CTA Physical Link Errors Summed Set...

Page 236: ...Parameters This command has one parameter Command Example Root show thresholdAlerts log Output The threshold alert log data displays as a table that includes the following properties clear This option...

Page 237: ...Too Short Delimiter Errors CTA Delimiter Errors Address ID Errors CTA Address ID Errors Cls2 BusiedFrms CTA Class 2 Busied Frames Cls2 RejectedFrms CTA Class 2 Rejected Frames Cls3 DiscardFrms CTA Cl...

Page 238: ...2 Tx Util 85 120 03 01 02 02 58A CTA Alert 1 130 CRC Errors 100 60 show zoning Syntax zoning Purpose This command shows the zoning configuration saved on the fabric Parameters This command has no par...

Page 239: ...omain 10 Port 6 ZoneMember Domain 15 Port 2 ZoneMember Domain 2 Port 63 ZoneMember 10 00 00 00 C9 22 9B 64 ZoneMember 10 00 00 00 C9 22 9B BD Zone TheNotSoUltimateZone ZoneMember 10 00 00 00 C9 22 9B...

Page 240: ...2 2 196 Enterprise Operating System Command Line Interface User Manual show...

Page 241: ...sy Description The switch cannot process any requests at this time Action Re submit the request Message Error 007 Not Authorized Description You are unable to get write authorization to save the confi...

Page 242: ...ntain 0 255 characters Enter a location with 0 255 characters and re submit If spaces are used enclose the location in quotation marks Message Error 011 Invalid Switch Contact Description The value en...

Page 243: ...nvalid Action The R_A_TOV is entered in tenths of a second and must be entered as an integer in the range 10 1200 1 second to 120 seconds The R_A_TOV value must be larger than the E_D_TOV value Check...

Page 244: ...he command in config switch priority on page 2 75 Message Error 029 Invalid Gateway Address Description The value entered for the gateway address is invalid Action The new gateway address for the Ethe...

Page 245: ...dress for the SNMP interface must be entered in dotted decimal format e g 10 0 0 0 Enter an appropriate SNMP trap address and re submit Message Error 034 Duplicate Community Names Require Identical Wr...

Page 246: ...nd re submit Message Error 039 Invalid Year Description The value of the year entered for the new system date is invalid Action The format of the date parameter must be mm dd yyyy or mm dd yyyy The ye...

Page 247: ...or SNMP A new community can be added only after a current community is removed Make the appropriate changes and re submit Message Error 045 Not Allowed While Switch Online Description The entered comm...

Page 248: ...Deadtime entered is invalid Action Enter a valid Deadtime value Valid values are 0 to 1440 Message Error 053 Invalid RADIUS Key Description The RADIUS key entered is invalid Action Enter a valid RADIU...

Page 249: ...must be unique Make the appropriate changes and re submit Message Error 060 Invalid Number of Zone Members Description The entered command tried to add more zone members than the zone can hold Action...

Page 250: ...e configuration changes from this interface the API interface will need to update to allow this interface to make changes Message Error 065 Cannot remove the last CLI user with Administrator rights De...

Page 251: ...d because a backup FRU is not installed Action Insert a backup FRU and re submit the request or consult the installation service manual for this product for appropriate action Message Error 073 Port N...

Page 252: ...er zone set for this product Action Reduce the number of members in one or more zones and re submit the command Message Error 077 Not Allowed While Port Is Failed Description The port selected is in a...

Page 253: ...Message Error 083 Not Allowed in Open Fabric Mode Description This request cannot be completed while this switch is operating in Open Fabric 1 0 mode Action Configure the interop mode to McDATA Fabri...

Page 254: ...and Message Error 093 Not Allowed While FICON MS Is Installed Description This request cannot be completed because FICON Management Server is installed Action This operation is not supported No action...

Page 255: ...e Error 103 Port Diagnostic In Progress Description The request cannot be completed because a port diagnostic is running Action Wait for the diagnostic to complete Message Error 104 System Diagnostic...

Page 256: ...8 Invalid TTA Type Description The type of the throughput threshold alert has not been set Action Set the type of the TTA then try to activate the alert Message Error 109 Invalid CTA Type Description...

Page 257: ...f 2 Gb sec Description The request cannot be completed because the switch is not capable of operating at 2 Gb sec Action Consult the installation service manual to determine the speed capabilities of...

Page 258: ...Invalid Credit Starvation Threshold Description An invalid credit starvation threshold has been entered Action Submit the request with a valid value The credit starvation threshold must be in the ran...

Page 259: ...6 Action The number of entries in the Switch Binding Membership List is limited to 256 Make sure that the list including the managed switch contains no more than 256 entries Message Error 137 Invalid...

Page 260: ...an invalid insistent domain ID state has been submitted Action The insistent domain ID state must be set to either enable or disable For more information see config switch insistDomainId on page 2 73...

Page 261: ...security configuration without first installing the SANtegrity feature key Action If this key has not been installed contact your sales representative Message Error 146 Fabric Binding May Not Be Deac...

Page 262: ...hat this can be disruptive to the fabric Message Error 151 Invalid Open Systems Management Server State Description The request cannot be completed because the OSMS state submitted is invalid Action T...

Page 263: ...hen there are several approaches to take This request may be completed most non disruptively by blocking the port or physically removing the device from the managed switch to which this device is atta...

Page 264: ...Message Error 161 The Switch IP Access Control List is Empty Description The management interface IP address is not in the list Action The management IP must be in the list or the current connection...

Page 265: ...he port is in the inactive state and diagnostics cannot be run Action The port state must change out of the inactive state Message Error 168 Duplicate member in the list Description The member is alre...

Page 266: ...ntry Message Error 173 Invalid value Description The value being entered is invalid Action Enter a valid value Message Error 174 Invalid list data Description The list data is invalid Action Correct t...

Page 267: ...ain IDs must be enabled Description To complete this command Insistent Domain IDs must be enabled Action Enabled Insistent Domain IDs Message Error 180 Too many management interface users Description...

Page 268: ...r this Fencing Policy Type Description The entered limit is invalid Action Enter a valid limit Message Error 186 Cannot Block this Port Description Port is not blockable Action Enter a valid port numb...

Page 269: ...fencing policy may not be defined without removing an existing port fencing policy from the list Action A total of 14 policies may be defined for port fencing A new policy can be added only after a cu...

Page 270: ...ot be enabled if they have the same port type Action Make sure the policy that is being enabled doesn t have the same port type as a policy that is enabled Message Error 196 Cannot enable two policies...

Page 271: ...service representative with further problems Message Error 203 Another Client Has Change Authorization Description Another user is currently making changes to this switch Action Be sure all parameters...

Page 272: ...n Be sure all parameters have been entered correctly and re submit Contact your service representative with continued problems Message Error 211 Duplicate Zone Description Two or more zone names in th...

Page 273: ...be a reduction in the number of zones in the zone set a reduction of members in a zone or a reduction of zone name lengths Message Error 216 No Attached Nodes Exist Description There are no attached...

Page 274: ...ot run diagnostics while a device is logged in to the port Description Diagnostics cannot be run while a device is logged into the port Action Block the port to run diagnostics Message Error 221 Canno...

Page 275: ...Description The value entered for the SNMP community name is invalid Action The community name must not exceed 32 characters in length Duplicate community names are allowed but corresponding write aut...

Page 276: ...the manual that corresponds to the attempted command Parameters must be typed exactly to specification to be recognized correctly by the CLI Message Error 232 Invalid Domain ID Description The domainI...

Page 277: ...he entered command is misspelled or the prompt is not positioned at the right place in the CLI command tree for this command For the appropriate syntax see the section of the manual that corresponds t...

Page 278: ...abric binding member Description The user requested to add an entry to the fabric binding list that is already a member of the list Action Verify that the correct entry both WWN and Domain ID is being...

Page 279: ...cified is not a valid number Action Use the table output by the command perf counterThreshAlerts showStatisticsTable to find a valid counter value Message Error 248 A counter must be assigned to this...

Page 280: ...Remove a Member Currently Interacting with the Fabric Description Current members of the fabric must be included in the Fabric Binding List Action Do not remove active fabric members from the pending...

Page 281: ...is out of range Action Select a valid duration value Message Error 259 Invalid threshold alert name Description The name of the threshold alert is incorrect Action The threshold alert name does not e...

Page 282: ...ge Error 264 The Preferred Path feature key is not installed Description The preferred path feature key must be installed Action Install the preferred path feature key Message Error 265 Duplicate thre...

Page 283: ...and 1440 minutes Description The desired deadtime value is invalid Action Select a deadtime value between 0 and 1440 Message Error 272 Invalid IP address and port combination Description The desired h...

Page 284: ...rror 277 Roles cannot be assigned to a username with this interface Description The role of the selected username is not configurable Action This operation is not supported No action necessary Message...

Page 285: ...hosts may be defined for the FICON CUP Zoning host control list A new host can be added only after a current host is removed Make the appropriate changes and re submit Message Error 285 WWN not found...

Page 286: ...ror 290 No Optic Installed Description There is not an optic in the port for the specified port number Action Select a different port number or plug in an optic Message Error 291 Port Inaccessible Des...

Page 287: ...ttings Action Modify the EPort authentication settings Message Error 297 Cannot delete last NPort user with current setting authentication setting Description You cannot remove the last NPort user wit...

Page 288: ...ver undefined Description You cannot perform the operation until a RADIUS server is configured You cannot enable RADIUS Authentication if there is not RADIUS server configured Action Configure a RADIU...

Page 289: ...agement Server is disabled Action Enabled Open Systems Management Server before enabling CT Outgoing Authentication Message Error 306 CT Outgoing Authentication is enabled Description You cannot disab...

Page 290: ...A A 50 Enterprise Operating System Command Line Interface User Manual...

Page 291: ...by release and are in alphabetical order within the release Table B 1 Commands and Releases First E OS Release Command 7 0 config features NPIV 7 0 config fencing addPolicy 7 0 config fencing addPort...

Page 292: ...security authentication interface api sequence 7 0 config security authentication interface cli sequence 7 0 config security authentication interface eport outgoing 7 0 config security authentication...

Page 293: ...ret 7 0 config security authentication user 7 0 config security authentication user add 7 0 config security authentication user delete 7 0 config security authentication user modify 7 0 config securit...

Page 294: ...og noWrap 7 0 show fabricLog wrap 7 0 show fabric principal 7 0 show fencing policies 7 0 show ficonCUPZoning 7 0 show ficonMS 7 0 show NPIV config 7 0 show openSysMS config 7 0 show port config 7 0 s...

Page 295: ...dAlerts alerts 6 1 show thresholdAlerts log 5 3 config enterpriseFabMode setState 5 3 config features openTrunking 5 3 config ficonMS setMIHPTO 5 3 config NPIV maxPortIDs 5 3 config switch ltdFabRSCN...

Page 296: ...thernet 4 0 config ip show 4 0 config port blocked 4 0 config port fan 4 0 config port name 4 0 config port show 4 0 config port speed 4 0 config port type 4 0 config security fabricBinding 4 0 config...

Page 297: ...contact 4 0 config system date 4 0 config system description 4 0 config system location 4 0 config system name 4 0 config system show 4 0 config zoning activateZoneSet 4 0 config zoning addPortMem 4...

Page 298: ...ng 4 0 maint port beacon 4 0 maint port reset 4 0 maint system beacon 4 0 maint system clearSysError 4 0 maint system ipl 4 0 maint system resetConfig 4 0 maint system setOnlineState 4 0 perf class2 4...

Page 299: ...4 0 show port info 4 0 show port nodes 4 0 show port status 4 0 show port technology 4 0 show security fabricBinding 4 0 show security portBinding 4 0 show security switchBinding 4 0 show switch 4 0 s...

Page 300: ...B B 10 Enterprise Operating System Command Line Interface User Manual...

Page 301: ...finitions from this text are identified by E IBM Dictionary of Computing ZC20 1699 Definitions from this text are identified by D Information Technology Vocabulary developed by Subcommittee 1 SC1 Join...

Page 302: ...ing for undefined zones or aliases See also zone zone set AL_PA See arbitrated loop physical address arbitrated loop physical address AL_PA A 1 byte value used in the arbitrated loop topology that ide...

Page 303: ...tion C channel A point to point link that transports data from one point to the other Class 2 Fibre Channel service Provides a connectionless not dedicated service with notification of delivery or non...

Page 304: ...ector or switch microprocessor The CTP card also initializes hardware components of the system after power on The card may contain an RJ 45 twisted pair connector control unit A hardware unit that con...

Page 305: ...automatically allocated to each switch in the fabric by the principal switch The preferred domain ID is the domain ID value that a switch requests from the principal switch If the value has not been...

Page 306: ...pology and serves as the basis for the Institute of Electrical and Electronics Engineers IEEE 802 3 standard which specifies the physical and software layers exchange fabric membership data An SW_ILS...

Page 307: ...ugh which data in the form of light pulses is transmitted It is used for high speed transmissions over medium 200 m to long 10 km distances Fibre Channel FC Integrated set of standards recognized by A...

Page 308: ...ddress is XXX XXX XXX XXX Gb s Acronym for gigabits per second generic port G_Port Physical interface on a director or switch that can function either as a fabric port F_Port or an expansion port E_Po...

Page 309: ...cs The concept includes the specification of the connection of two devices having different functions T 2 Hardware software or both that link systems programs or devices D Internet protocol IP Network...

Page 310: ...ork in a localized geographical area for example a building or campus whose communications technology provides a high bandwidth medium to which many nodes are connected D See also storage area network...

Page 311: ...xxx xxx xxx xxx or a domain name as administered on a customer network node In Fibre Channel protocol an end device server or storage device that is or can be connected to a switched fabric See also...

Page 312: ...igured in the same zone Offline when the director or switch is set offline all ports are set offline The director or switch transmits the offline sequence OLS to attached devices and the devices canno...

Page 313: ...nside a hardware cabinet port name Name that the user assigns to a particular port through the Element Manager application preferred domain ID Configured value that a switch will request from the Prin...

Page 314: ...upports director or switch configuration statistics monitoring and basic operations With director or switch firmware installed administrators or operators with a browser capable personal computer PC a...

Page 315: ...sed with the correct SNMP community name simple network management protocol management station SNMP management station An SNMP workstation personal computer PC used to oversee the SNMP network SNMP Se...

Page 316: ...igured into each switch in a fabric that determines its relative likelihood of becoming the fabric s principal switch Lower values indicate higher likelihood of becoming the principal switch A value o...

Page 317: ...ssible error has been detected See also error message information message World Wide Names WWN Eight byte string that uniquely identifies a Fibre Channel entity that is a port a node a switch a fabric...

Page 318: ...e Interface User Manual Glossary zoning Grouping of several devices by function or by location All devices connected to a connectivity product such as the director or switch may be configured into one...

Page 319: ...show 2 139 authentication configuring E port 2 34 2 35 configuring interface 2 34 configuring N port 2 36 configuring Open Systems 2 37 2 38 configuring outgoing 2 33 configuring port 2 40 configuring...

Page 320: ...fect immediately 2 51 2 84 commenting scripts 1 20 config command 2 5 configuration data resetting 2 95 configuration resetting 2 97 congestion unresolved 2 109 congestion threshold OpenTrunking 2 106...

Page 321: ...dd attached members 2 53 pending FBML show 2 57 replace pending 2 56 replace pending FBML 2 56 security 2 51 show 2 180 show pending 2 57 terms attached 2 52 local 2 52 unattached 2 52 fabric binding...

Page 322: ...ounters 2 104 link incident log 2 154 link sequence counts 2 120 local fabric binding terminology 2 52 log Embedded Frame settings 2 140 threshold alert 2 192 view 2 144 logging in 1 14 logging out 1...

Page 323: ..._credits 2 26 configuring WWN binding 2 59 error counters 2 102 IDs NPIV 2 22 information 2 166 link counters 2 104 name 2 26 nodes 2 167 optical diagnostics 2 169 port statistics 2 102 port technolog...

Page 324: ...ng N port authentication 2 36 configuring Open Systems authentication 2 37 2 38 configuring outgoing authentication 2 33 configuring port state 2 40 configuring RADIUS server deadtime 2 42 configuring...

Page 325: ...alert list 2 189 threshold alert log 2 192 threshold alert settings 2 135 WWN 2 148 show commands active zoning configuration 2 92 all 2 138 configuration for port 2 27 features 2 9 order of output 1...

Page 326: ...nd time 2 82 system description 2 82 system error light clearing 2 97 system location 2 83 system name 2 83 T tabular output 1 17 technical support xvii Telnet client session 1 2 connection loss of 1...

Page 327: ...ew logs 2 142 2 143 2 145 2 146 W web site McDATA xvi xviii web based interface 1 2 enabling Telnet 1 22 work area 2 84 world wide name members adding 2 87 deleting 2 90 wrap count 2 99 2 100 WWN port...

Page 328: ...Enterprise Operating System Command Line Interface User Manual i 10 Index...